000 03408cam a2200337 a 4500
003 EG-GiCUC
005 20250223032904.0
008 211226s2021 ua dho f m 000 0 eng d
040 _aEG-GiCUC
_beng
_cEG-GiCUC
041 0 _aeng
049 _aDeposite
097 _aM.Sc
099 _aCai01.09.09.M.Sc.2021.Sh.E
100 0 _aSherine Osama Hussein Elebiary
245 1 4 _aThe effect on dental implant stability with and without using 1:1 mixture of autogenous bone and anorganic bovine bone minerals particulates in immediate implant placement in the dental esthetic zone :
_bA randomized clinical trial /
_cSherine Osama Hussein Elebiary ; Supervised Mohammed Mokhtar Khashaba , Mohammed Atef
246 1 5 _aالتأثيرعلى ثبات الزراعة السنية مع و بدون استخدام خليط ١:١ من جزيئات عظمية ذاتية المنشأ و جزيئات عظمية حيوانية المنشأ فى الزراعة الفورية في المنطقة السنية الجمالية:
_bتجربة سريرية عشوائية
260 _aCairo :
_bSherine Osama Hussein Elebiary ,
_c2021
300 _a144 P. :
_bcharts , facsimiles , photoghraphs ;
_c25cm
502 _aThesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Prosthodontics
520 _aAIM: The aim of this study is to evaluate implant stability, radiographic bone changes in terms of horizontal and vertical bone loss and pink esthetic score in immediate implant installation and immediate provisionalization with and without grafting the jumping gap with a mixture of 1:1 autogenous and xenograft particulates. Methodology: Twenty- four patients with non-restorable single tooth in the maxillary anterior region indicated for extraction were enrolled in this study, all received immediate implant placement with immediate temporization.These patients were randomly selected from the Outpatient Clinic of the Oral and Maxillofacial department of Cairo University and equally divided into study and control group.The twelve patients in the study group received a treatment of grafting the jumping distance created after implant placement.This graft was a mixture of 1:1 xenograft to autogenous bone particulates.The autogenous bone was collected by low-speed drilling from within the socket.The twelve patients of the control group did not receive the graft. Outcome measures were: Secondary Implant Stability, amount of marginal bone loss (Horizontal and Vertical), PES after 6 months. Results: The mean implant stability quotient for study group was 68.5± 3.1 and increased to 77.6 ± 3.7 after 6 months, while for the control group it was 66.3± 5.4 and increased to 74.2 ± 4.5 after 6 months. Mean results regarding horizontal bone loss at platform level for study group was 0.09 ± 0.06 and was 0.26± 0.27 for control group, at mid-implant level was 0.5± 0.26 for study group and 0.43± 0.48 for contro1 group, at apex level mean results were 0.42 ± 0.25 for study group and 0.59± 0.52 for control group
530 _aIssued also as CD
653 4 _aExposure
653 4 _aImplant stability
653 4 _aUncovering
700 0 _aMohammed Atef ,
_eSupervisor
700 0 _aMohammed Mokhtar Khashaba ,
_eSupervisor
856 _uhttp://172.23.153.220/th.pdf
905 _aNazla
_eRevisor
905 _aShimaa
_eCataloger
942 _2ddc
_cTH
999 _c83705
_d83705