000 | 03408cam a2200337 a 4500 | ||
---|---|---|---|
003 | EG-GiCUC | ||
005 | 20250223032904.0 | ||
008 | 211226s2021 ua dho f m 000 0 eng d | ||
040 |
_aEG-GiCUC _beng _cEG-GiCUC |
||
041 | 0 | _aeng | |
049 | _aDeposite | ||
097 | _aM.Sc | ||
099 | _aCai01.09.09.M.Sc.2021.Sh.E | ||
100 | 0 | _aSherine Osama Hussein Elebiary | |
245 | 1 | 4 |
_aThe effect on dental implant stability with and without using 1:1 mixture of autogenous bone and anorganic bovine bone minerals particulates in immediate implant placement in the dental esthetic zone : _bA randomized clinical trial / _cSherine Osama Hussein Elebiary ; Supervised Mohammed Mokhtar Khashaba , Mohammed Atef |
246 | 1 | 5 |
_aالتأثيرعلى ثبات الزراعة السنية مع و بدون استخدام خليط ١:١ من جزيئات عظمية ذاتية المنشأ و جزيئات عظمية حيوانية المنشأ فى الزراعة الفورية في المنطقة السنية الجمالية: _bتجربة سريرية عشوائية |
260 |
_aCairo : _bSherine Osama Hussein Elebiary , _c2021 |
||
300 |
_a144 P. : _bcharts , facsimiles , photoghraphs ; _c25cm |
||
502 | _aThesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Prosthodontics | ||
520 | _aAIM: The aim of this study is to evaluate implant stability, radiographic bone changes in terms of horizontal and vertical bone loss and pink esthetic score in immediate implant installation and immediate provisionalization with and without grafting the jumping gap with a mixture of 1:1 autogenous and xenograft particulates. Methodology: Twenty- four patients with non-restorable single tooth in the maxillary anterior region indicated for extraction were enrolled in this study, all received immediate implant placement with immediate temporization.These patients were randomly selected from the Outpatient Clinic of the Oral and Maxillofacial department of Cairo University and equally divided into study and control group.The twelve patients in the study group received a treatment of grafting the jumping distance created after implant placement.This graft was a mixture of 1:1 xenograft to autogenous bone particulates.The autogenous bone was collected by low-speed drilling from within the socket.The twelve patients of the control group did not receive the graft. Outcome measures were: Secondary Implant Stability, amount of marginal bone loss (Horizontal and Vertical), PES after 6 months. Results: The mean implant stability quotient for study group was 68.5± 3.1 and increased to 77.6 ± 3.7 after 6 months, while for the control group it was 66.3± 5.4 and increased to 74.2 ± 4.5 after 6 months. Mean results regarding horizontal bone loss at platform level for study group was 0.09 ± 0.06 and was 0.26± 0.27 for control group, at mid-implant level was 0.5± 0.26 for study group and 0.43± 0.48 for contro1 group, at apex level mean results were 0.42 ± 0.25 for study group and 0.59± 0.52 for control group | ||
530 | _aIssued also as CD | ||
653 | 4 | _aExposure | |
653 | 4 | _aImplant stability | |
653 | 4 | _aUncovering | |
700 | 0 |
_aMohammed Atef , _eSupervisor |
|
700 | 0 |
_aMohammed Mokhtar Khashaba , _eSupervisor |
|
856 | _uhttp://172.23.153.220/th.pdf | ||
905 |
_aNazla _eRevisor |
||
905 |
_aShimaa _eCataloger |
||
942 |
_2ddc _cTH |
||
999 |
_c83705 _d83705 |