| 000 | 02844cam a2200337 a 4500 | ||
|---|---|---|---|
| 003 | EG-GiCUC | ||
| 005 | 20250223032905.0 | ||
| 008 | 271221s2021 ua dho f m 000 0 eng d | ||
| 040 |
_aEG-GiCUC _beng _cEG-GiCUC |
||
| 041 | 0 | _aeng | |
| 049 | _aDeposite | ||
| 097 | _aPh.D | ||
| 099 | _aCai01.24.03.Ph.D.2021.Wa.E | ||
| 100 | 0 | _aWalid Ahmed Kamal | |
| 245 | 1 | 0 |
_aEffect of high-level laser therapy on shoulder mobility in subacromial impingement syndrome / _c Walid Ahmed Kamal ; Supervised Mahmood Saber , Khalid Aiad |
| 246 | 1 | 5 | _aتأثير الليزر عالى الجهد على حركة مفصل الكتف فى متلازمة اختناق تحت الأخرم |
| 260 |
_aCairo: _bWalid Ahmed Kamal , _c2021 |
||
| 300 |
_a78 P . : _bcharts , facsimiles , photographes ; _c25cm |
||
| 502 | _aThesis (Ph.D.) - Cairo University - National Institute of Laser Enhanced Sciences - Department of Laser Application in Medical & Biological | ||
| 520 | _aBackground. The effect of high-level laser on shoulder mobility in subacromial impingement syndrome had been not investigated yet. Objectives. to investigate the effect of high- level laser therapy on shoulder mobility in subacromial impingement syndrome. Design. A Prospective, Randomized, pre - post- Test, controlled trial. Setting. outpatient clinic of Cleopatra Hospital {u2013} Egypt. The Study was conducted between June 2017 and Feb 2018. participants. forty Patients who were diagnosed with 1 - 2 stage impingement syndrome pain was Randomly divided into two equal groups. Interventions. Group (A) received a program of Neodymium- yttrium aluminum Garnet Laser 1064 nm wave Length Hiro 3 high level pulsed Laser was used in the study, Power of 8 W, dose of 12 J/cm2 and Total maximum energy of 10000 J were Applied for 15 min and duration for single impulse 150 `us, fluency 760 mj, two sessions per week over six weeks' period in addition to exercise Group (B) Received Exercise in the form of Pendulum Ex. For 5 minutes, strengthen Ex for Anterior fiber of deltoid, stretching Ex for sub scapularis muscle and anterior and posterior capsule. Main outcome measure. Visual Analogue Scale (VAS), electro goniometer, Ultrasonography Results. There was a statistically significant Reduction in VAS score, and improvement of mobility of shoulder in laser group compared with control group (p< 0.05) Conclusion. High level laser Therapy was yielding more improvement for shoulder mobility in impingement syndrome | ||
| 530 | _aIssued also as CD | ||
| 653 | 4 | _aHigh level Laser Therapy | |
| 653 | 4 | _aImpingement syndrome | |
| 653 | 4 | _aShoulder mobility | |
| 700 | 0 |
_aKhalid Aiad , _eSupervisor |
|
| 700 | 0 |
_aMahmood Saber , _eSupervisor |
|
| 856 | _uhttp://172.23.153.220/th.pdf | ||
| 905 |
_aAmira _eCataloger |
||
| 905 |
_aNazla _eRevisor |
||
| 942 |
_2ddc _cTH |
||
| 999 |
_c83729 _d83729 |
||