Clinical Assessment Of Indirect Restorations Fabricated From Cad Cam Nano Hybrid Composite Blocks Versus Ceramic Blocks In Badly Broken Teeth: (Record no. 170448)
[ view plain ]
000 -LEADER | |
---|---|
fixed length control field | 09732namaa22004331i 4500 |
003 - CONTROL NUMBER IDENTIFIER | |
control field | OSt |
005 - أخر تعامل مع التسجيلة | |
control field | 20250223033419.0 |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
fixed length control field | 250127s2022 |||a|||f m||| 000 0 eng d |
040 ## - CATALOGING SOURCE | |
Original cataloguing agency | EG-GICUC |
Language of cataloging | eng |
Transcribing agency | EG-GICUC |
Modifying agency | EG-GICUC |
Description conventions | rda |
041 0# - LANGUAGE CODE | |
Language code of text/sound track or separate title | eng |
Language code of summary or abstract | eng |
-- | ara |
049 ## - Acquisition Source | |
Acquisition Source | Deposit |
082 04 - DEWEY DECIMAL CLASSIFICATION NUMBER | |
Classification number | 617.6 |
092 ## - LOCALLY ASSIGNED DEWEY CALL NUMBER (OCLC) | |
Classification number | 617.6 |
Edition number | 21 |
097 ## - Degree | |
Degree | Ph.D |
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC) | |
Local Call Number | Cai01.09.03.Ph.D.2022.Ha.C |
100 0# - MAIN ENTRY--PERSONAL NAME | |
Authority record control number or standard number | Haneen Ahmed Shafik Elmoselhy, |
Preparation | preparation. |
245 10 - TITLE STATEMENT | |
Title | Clinical Assessment Of Indirect Restorations Fabricated From Cad Cam Nano Hybrid Composite Blocks Versus Ceramic Blocks In Badly Broken Teeth: |
Remainder of title | One Year Follow Up Randomized Clinical Trial/ |
Statement of responsibility, etc. | Haneen Ahmed Shafik Elmoselhy ; Supervisors : Prof. Dr. Olfat EL Sayed Hassanien, Prof. Dr. Mohamed Fouad Haridy, Ass. Prof. Maha Abd El Salam El Baz. |
246 15 - VARYING FORM OF TITLE | |
Title proper/short title | : التقييم الاكلينيكي لمدة عام لترميمات الغير مباشرة المصممة بالكمبيوترلمادة الكومبوزيت مقارنة بمادة السيراميك في الاسنان المحطم |
Remainder of title | /دراسة سريرية عشوائيه |
264 #0 - PRODUCTION, PUBLICATION, DISTRIBUTION, MANUFACTURE, AND COPYRIGHT NOTICE | |
Date of production, publication, distribution, manufacture, or copyright notice | 2022. |
300 ## - PHYSICAL DESCRIPTION | |
Extent | 136 pages : |
Other physical details | illustrations ; |
Dimensions | 25 cm. + |
Accompanying material | CD. |
336 ## - CONTENT TYPE | |
Content type term | text |
Source | rda content |
337 ## - MEDIA TYPE | |
Media type term | Unmediated |
Source | rdamedia |
338 ## - CARRIER TYPE | |
Carrier type term | volume |
Source | rdacarrier |
502 ## - DISSERTATION NOTE | |
Dissertation note | Thesis (Ph.D)-Cairo University, 2022. |
504 ## - BIBLIOGRAPHY, ETC. NOTE | |
Bibliography, etc. note | Bibliography: pages 124-132. |
520 ## - SUMMARY, ETC. | |
Summary, etc. | Resin composite materials have been quickly developed in the latest few years. Direct resin <br/>composite restorations become the gold standard for restoring intra-coronal cavities. While <br/>for the extra coronal cavities, the indirect resin composite onlays be inclined to replace <br/>metallic restorations in most situations being more esthetic and conservative with lower cost <br/>and may give a quality comparable to Ceramics<br/>The aim of the study was to compare one-year clinical performance of indirect restorations <br/>fabricated from nano hybrid composite and ceramic CAD CAM blocks using modified <br/>USPHS criteria after different follow up periods (either immediate, 6 months and one year)<br/>In two parallel groups (n= 50 restorations), participants having badly broken vital teeth <br/>minimum of two remaining wall were randomly enrolled in this trial and received indirect <br/>Restoration Either resin composite blocks (Brilliant, Coltene, Switzerland) or IPS Emax Cad <br/>Lithium Disilicate were cemented with Dual cure resin cement according to the <br/>manufacturers’ instructions with the corresponding adhesive system. The restorations were <br/>assessed using modified USPHS criteria by two independent blinded assessors at baseline, 6 <br/>months and 1-year follow up visits. Data was obtained and analyzed using Independent <br/>Student-t test, Chi-square and McNemar test for inter and intragroup comparisons. The <br/>significance level was set at P ≤ 0.05.<br/>All the 50 participants completed the trial. There was statistically significant difference <br/>between both tested materials for all USPHS criteria regarding Marginal integrity and <br/>Marginal discoloration at 6 months Follow up but with no statistically significant difference <br/>at 1 year Follow up.<br/>Both materials showed an acceptable successful clinical performance along 1-year follow-up <br/>period.<br/>Under limitation of current study, the following conclusions can be driven: <br/>1)Resin composite and ceramic CAD/CAM blocks used in restoration of mutilated <br/>vital teeth showed a satisfactory clinical performance along one year follow-up <br/>period.<br/>2)The indirect restorations fabricated from CAD/CAM resin composite blocks <br/>showed excellent marginal quality compared to conventional ceramic restorations <br/>even after one year performance.<br/>3)The use of resilient CAD/CAM resin composite blocks could be considered a <br/>perfect choice in the restoration of badly broken vital posterior teeth.<br/>4)Both resin composite and ceramic CAD/CAM blocks restoration were affected <br/>minimally by time with acceptable clinical performance.<br/>134<br/>Clinical recommendations:<br/>1)Longer follow up period (2 years) is highly recommended to evaluate the clinical <br/>performance of the used materials. <br/>2)Testing resin composite blocks in different clinical situations e.g. endodontically <br/>treated teeth or in patients with high occlusal stresses is highly advocated to confirm <br/>their general performance.<br/>3)Using stone replica in the evaluation of marginal fit as an auxiliary aid, is highly <br/>recommended with the subjective assessment of evaluators.<br/> |
520 ## - SUMMARY, ETC. | |
Summary, etc. | تم تطوير المواد المركبة من الراتينج بسرعة في السنوات القليلة الماضية. أصبحت الترميمات المركّبة من الراتينج المباشر هي المعيار الذهبي لاستعادة التجاويف داخل الإكليل. بينما في التجاويف التاجية الإضافية ، تميل حشوات الراتينج غير المباشرة لتحل محل الترميمات المعدنية في معظم الحالات كونها أكثر جمالية وتحفظًا بتكلفة أقل وقد تعطي جودة مماثلة للسيراميك<br/>كان الهدف من الدراسة هو مقارنة الأداء السريري لمدة عام للترميمات غير المباشرة المصنّعة من كتل النانو الهجينة والسيراميك CAD CAM باستخدام معايير USPHS المعدلة بعد فترات متابعة مختلفة (إما فورية ، 6 أشهر وسنة واحدة)<br/> في مجموعتين متوازيتين (ن = 50 ترميمًا) ، تم تسجيل المشاركين الذين أصيبوا بكسر في الأسنان الحيوية بشكل سيئ من جدارين متبقين بشكل عشوائي في هذه التجربة وتلقوا ترميمًا غير مباشر إما كتل الراتنج المركبة (بريليانت ، كولتين ، سويسرا) أو IPS Emax Cad Lithium Disilicate كانت مدعمة بإسمنت راتينج ثنائي المعالجة وفقًا لتعليمات الشركات الصانعة مع نظام اللصق المقابل. تم تقييم عمليات الترميم باستخدام معايير USPHS المعدلة من قبل اثنين من المقيمين المكفوفين المستقلين في الأساس ، 6 أشهر و 1 سنة زيارات المتابعة. تم الحصول على البيانات وتحليلها باستخدام اختبار Student-t المستقل واختبار Chi-square و McNemar للمقارنات بين المجموعات وداخلها. تم تعيين مستوى الأهمية عند P 0.05.<br/>أكمل جميع المشاركين الخمسين المحاكمة. كان هناك فرق معتد به إحصائياً بين كلتا المادتين المختبرتين لجميع معايير USPHS فيما يتعلق بالسلامة الهامشية وتغير اللون الهامشي في 6 أشهر من المتابعة ولكن مع عدم وجود فرق معتد به إحصائياً في 1 سنة من المتابعة.<br/>أظهرت كلتا المادتين أداءً سريريًا مقبولًا مقبولًا على مدار فترة متابعة مدتها عام واحد<br/><br/>في ظل قيود الدراسة الحالية ، يمكن أن تكون الاستنتاجات التالية مدفوعة:<br/>1) أظهرت كتل الراتنج المركب والسيراميك CAD / CAM المستخدمة في ترميم الأسنان الحيوية المشوهة أداءً سريريًا مرضيًا على مدار فترة متابعة لمدة عام واحد.<br/>2) أظهرت الترميمات غير المباشرة المصنوعة من كتل راتنج CAD / CAM جودة هامشية ممتازة مقارنة بترميمات السيراميك التقليدية حتى بعد أداء عام واحد.<br/>3) يمكن اعتبار استخدام كتل راتينج CAD / CAM المرنة خيارًا مثاليًا في ترميم الأسنان الخلفية الحيوية المكسورة بشكل سيئ.<br/>4) تأثر كل من ترميم كتل الراتنج المركب والسيراميك CAD / CAM بشكل طفيف بمرور الوقت مع الأداء السريري المقبول.<br/> <br/>التوصيات السريرية:<br/>1) يوصى بشدة بفترة متابعة أطول (سنتان) لتقييم الأداء السريري للمواد المستخدمة.<br/>2) اختبار كتل الراتنج المركب في حالات سريرية مختلفة على سبيل المثال ينصح بشدة الأسنان المعالجة لبيا أو في المرضى الذين يعانون من ضغوط الإطباق العالية لتأكيد أدائهم العام.<br/>3) يوصى بشدة باستخدام نسخة متماثلة من الحجر في تقييم الملاءمة الهامشية كمساعدة مساعدة مع التقييم الذاتي للمقيمين.<br/> |
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE | |
Issues CD | Issues also as CD. |
546 ## - LANGUAGE NOTE | |
Text Language | Text in English and abstract in Arabic & English. |
650 #7 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
Topical term or geographic name entry element | Dentistry |
Source of heading or term | qrmak |
653 #0 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Randomized clinical trial |
-- | CAD/CAM composite restoration |
-- | CAD/CAM milling system |
-- | Ceramic Restoration |
-- | Emax: CAD/CAM |
-- | indirect restoration |
-- | composite |
-- | inlays |
700 0# - ADDED ENTRY--PERSONAL NAME | |
Personal name | Olfat EL Sayed Hassanien |
Relator term | thesis advisor. |
700 0# - ADDED ENTRY--PERSONAL NAME | |
Personal name | Mohamed Fouad Haridy |
Relator term | thesis advisor. |
700 0# - ADDED ENTRY--PERSONAL NAME | |
Personal name | Maha Abd El Salam El Baz |
Relator term | thesis advisor. |
900 ## - Thesis Information | |
Grant date | 01-01-2022 |
Supervisory body | Olfat EL Sayed Hassanien |
-- | Mohamed Fouad Haridy |
-- | Maha Abd El Salam El Baz |
Universities | Cairo University |
Faculties | Faculty of Dentistry |
Department | Department of Restorative and Esthetic Dentistry |
905 ## - Cataloger and Reviser Names | |
Cataloger Name | Aya Mohamed |
Reviser Names | Huda |
942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
Source of classification or shelving scheme | Dewey Decimal Classification |
Koha item type | Thesis |
Edition | 21 |
Suppress in OPAC | No |
Source of classification or shelving scheme | Home library | Current library | Date acquired | Inventory number | Full call number | Barcode | Date last seen | Effective from | Koha item type |
---|---|---|---|---|---|---|---|---|---|
Dewey Decimal Classification | المكتبة المركزبة الجديدة - جامعة القاهرة | قاعة الرسائل الجامعية - الدور الاول | 27.01.2025 | 90043 | Cai01.09.03.Ph.D.2022.Ha.C | 01010110090043000 | 27.01.2025 | 27.01.2025 | Thesis |