header

Assessment of the bone tunnel behaviour in ACL reconstruction with press fitt bone plug fixation / (Record no. 62665)

MARC details
000 -LEADER
fixed length control field 02486cam a2200349 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250223031817.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 171002s2014 ua dh f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level Ph.D
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.11.25.Ph.D.2014.Ta.A
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Tarek Benziad Morad Ewes
245 10 - TITLE STATEMENT
Title Assessment of the bone tunnel behaviour in ACL reconstruction with press fitt bone plug fixation /
Statement of responsibility, etc. Tarek Ben Ziad Morad Ewes ; Supervised Abdelaziz Singergy , Hisham Misbah , Hazem Farouk
246 15 - VARYING FORM OF TITLE
Title proper/short title تقييم سلوك النفق العظمى فى عمليه أعاده بناء الرباط الصليبى الأمامى بأستخدام طريقه الحشر بالأسطوانات العظميه
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Tarek Benziad Morad Ewes ,
Date of publication, distribution, etc. 2014
300 ## - PHYSICAL DESCRIPTION
Extent 168 P. :
Other physical details charts , facsimiles ;
Dimensions 25cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (Ph.D.) - Cairo University - Faculty of Medicine - Department of Orthopaedic Surgery
520 ## - SUMMARY, ETC.
Summary, etc. 1- autologous Replacement. 2-Mimic of the AM and PL bundle in a single tunnel 3-Primary stable for forced rehabilitation. 4-Minimum of bone defects 5- The bone graft is close to the anatomic site of the ACL foot print. This means no .bungee-effect. 6- Broad based contact under pressure between the graft and the bone give rigid fixation and early graft integration. 7- The press fit tunnel placement prevents synovial fluid entering into bone tunnel, decreases bleeding out of tunnels (less postoperative swelling) and reduces windshield wiper effect. 8- The intensive contact between bony wall of the tunnel and graft-collagen a long distance may accelerate graft incorporation. 9-. Reduction of the diameter of the bone tunnel after three months. Our findings confirm that press-fit fixation may result in less bone loss in the bone tunnel 10- The fact that we do not utilize implants for fixation prevents hardware discomfort and eventually surgical removal, facilitates revision surgery, avoids metal artefacts in MRI and lowers overall costs
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term ACL reconstruction
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Bone tunnel behaviour
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Press fitt bone plug fixation
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Abdelaziz Singergy ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Hazem Farouk ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Hisham Misbah ,
Relator term
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a>
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Enas
Reviser Cataloger
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.11.25.Ph.D.2014.Ta.A 01010110072692000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.11.25.Ph.D.2014.Ta.A 01020110072692000 22.09.2023 CD - Rom 72692.CD