header

Potentiometric determination of iron (II) and aluminium (III) using ion selective electrode modified with polymer / (Record no. 69880)

MARC details
000 -LEADER
fixed length control field 02017cam a2200313 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 190131s2018 ua d f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.12.08.M.Sc.2018.Mo.P
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Mohamed Abdelfattah Elsayed
245 10 - TITLE STATEMENT
Title Potentiometric determination of iron (II) and aluminium (III) using ion selective electrode modified with polymer /
Statement of responsibility, etc. Mohamed Abdelfattah Elsayed ; Supervised Eman Y. Z. Frag , Nahed Abdelfattah Abdelghany
246 15 - VARYING FORM OF TITLE
Title proper/short title باستخدام اقطاب ايونية انتقائية معالجة بالبوليمر (III) والالومنيوم (II)التقدير الجهدى لايونات الحديد
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Mohamed Abdelfattah Elsayed ,
Date of publication, distribution, etc. 2018
300 ## - PHYSICAL DESCRIPTION
Extent 89 P. :
Other physical details charts ;
Dimensions 25cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - Cairo University - Faculty of Science - Department of Analytical Chemistry
520 ## - SUMMARY, ETC.
Summary, etc. In this work we focused on the fabrication of a new chemically modified carbon paste electrodes for determination of Fe(II) and Al(III) ions based on polymer as ionophore. They were described for determination of the ions under investigation using potentiometric calibration and the experimental parameters were optimized according to ICH guidelines. The performance of such sensors in the potentiometric determination of Fe(II) and Al(III) ions in pure and water samples were compared with those of spectrophotometric and ICP methods. The surface characterization of the sensors was described using SEM, IR and EDX. Method validation parameters were carefully studied according to IUPAC recommendations
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Aluminium (III)
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Iron (II)
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Modified carbon paste electrodes
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Eman Y. Z. Frag ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Nahed Abdelfattah Abdelghany ,
Relator term
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Asmaa
Reviser Cataloger
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.12.08.M.Sc.2018.Mo.P 01010110077063000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.12.08.M.Sc.2018.Mo.P 01020110077063000 22.09.2023 CD - Rom 77063.CD