header

Immediate implant placement with deproteinized bovine bone (Tutogen) versus Platelet-rich fibrin as a space filling material in mandibular molars : (Record no. 72423)

MARC details
000 -LEADER
fixed length control field 02643cam a2200337 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250223032315.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 190615s2018 ua dho f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.09.09.M.Sc.2018.Ah.I
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Ahmed Hussein Elgarhy
245 10 - TITLE STATEMENT
Title Immediate implant placement with deproteinized bovine bone (Tutogen) versus Platelet-rich fibrin as a space filling material in mandibular molars :
Remainder of title Randomized clinical trial a protocol /
Statement of responsibility, etc. Ahmed Hussein Elgarhy ; Supervised Niveen Askar , Mohamed Atef Abdelrassoul
246 15 - VARYING FORM OF TITLE
Title proper/short title وضع الزرعات مباشرة بعد عمليه خلع الطاحون الأول أو الثاني السفلي مع وضع عظم بقري صناعي ضد وضع الصفائح الدمويه الغنيه بالفبريين فى الطواحين السفليه
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Ahmed Hussein Elgarhy ,
Date of publication, distribution, etc. 2018
300 ## - PHYSICAL DESCRIPTION
Extent 60 P. :
Other physical details charts , facsimiles ;
Dimensions 25cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Prosthodontics
520 ## - SUMMARY, ETC.
Summary, etc. The present study investigated the bone regeneration potential of xenografts versus Platelet-Rich fibrin in immediate implants in mandibular molars.Twenty patients with an age range of 18-45 were enrolled in this study. All patients were indicated for immediate implant placement with a total of 20 implants placed. The selection criteria was patient with at least 9 mm of residual bone height and sufficient inter-septal bone based upon the preoperative CBCT, to avoid inferior alveolar bone injury and free of any medical conditions that may impair bone healing. The atraumatic extraction was carried out using rotary instruments and periotomes. Implants were placed into the inter-septal bone of mandibular molar followed by placement of xenograft placement covered by collagen membrane and tissue approximating sutures were made. In the study group the implants are placed also in the interseptal bone followed by placement of Platelet rich fibrin as space filling material,The residual bone changes were measured 6 months post-operatively using the immediate post-operative Cone-beam as a baseline reference
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Deproteinized bovine bone
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Platelet-rich
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Tutogen
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Mohamed Atef Abdelrassoul ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Niveen Askar ,
Relator term
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a>
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Shimaa
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.09.09.M.Sc.2018.Ah.I 01010110078429000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.09.09.M.Sc.2018.Ah.I 01020110078429000 22.09.2023 CD - Rom 78429.CD