header

Accuracy of stitched CBCT using small field of view in the assessment of mandibular linear measurements versus the real measurements : (Record no. 73525)

MARC details
000 -LEADER
fixed length control field 02533cam a2200349 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250223032348.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 190827s2018 ua do f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.09.05.M.Sc.2018.Ja.A
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Jasmine Mohammed Aly
245 10 - TITLE STATEMENT
Title Accuracy of stitched CBCT using small field of view in the assessment of mandibular linear measurements versus the real measurements :
Remainder of title Pre-clinical study ,
Statement of responsibility, etc. Jasmine Mohammed Aly ; Supervised Hossam Kandil , Reham Hamdy , Mahmoud Abdelrauof Shalash
246 15 - VARYING FORM OF TITLE
Title proper/short title دقه القياسات الخطيه للاشعه المقطعيه مخروطيه الشعاع باستخدام مجال الرؤيه الصغيره المخيطه مقارنه بالقياسات الحقيقيه :
Remainder of title دراسه ما قبل السريريه
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Jasmine Mohammed Aly ,
Date of publication, distribution, etc. 2018
300 ## - PHYSICAL DESCRIPTION
Extent 91 P. :
Other physical details charts , photographs ;
Dimensions 25cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Oral (Radiology and Diagnosis)
520 ## - SUMMARY, ETC.
Summary, etc. This preclinical study assessed the accuracy of linear measurements conducted on stitched small field of view (SSFOV) CBCT images of 15 dry human mandibles compared to the real measurements conducted directly on the mandibles using digital caliper. A composite image for each mandible was obtained by automatic and manual stitching of 7 small FOVs using the PlanmecaRomexis software. The scans were captured using PlanmecaPromax 3D MID ultra- low dose mode (ULD). The 15 mandibles were immersed under water for soft tissue simulation and all the linear measurements were conducted under the guide of RO markers. The results showed no statistically significant difference between the direct linear measurements conducted on the 15 dry human mandibles and the measurements conducted on SSFOV CBCT images. The maximum mean difference of 0.56 mm between the direct linear measurements and the SSFOV CBCT measurements. 1.01 % error was found accepted and within the limits of the 5% clinically permissible erro
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term CBCT
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term CT
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term MDCT
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Hossam Kandil ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Mahmoud Abdelrauof Shalash ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Reham Hamdy ,
Relator term
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a>
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Asmaa
Reviser Cataloger
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.09.05.M.Sc.2018.Ja.A 01010110078976000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.09.05.M.Sc.2018.Ja.A 01020110078976000 22.09.2023 CD - Rom 78976.CD