header

Evaluation of implant placement in extraction sockets versus healed bony sites with or without immediate loading / (Record no. 78048)

MARC details
000 -LEADER
fixed length control field 02983cam a2200337 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250223032607.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 201004s2018 ua dh f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.09.08.M.Sc.2018.Mo.E
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Mohammed Hussein Marza Alatimoori
245 10 - TITLE STATEMENT
Title Evaluation of implant placement in extraction sockets versus healed bony sites with or without immediate loading /
Statement of responsibility, etc. Mohammed Hussein Marza Alatimoori ; Supervised Amr Ahmed Fouad Zahran , Ahmad Reda Abdulrahman
246 15 - VARYING FORM OF TITLE
Title proper/short title تقييم وضع غرسات سنية فى تجاويف الاسنان بعد الخلع مقابل وضعها فى مواقع عظمية ملتئمة مع أو بدون التحميل الفورى
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Mohammed Hussein Marza Alatimoori ,
Date of publication, distribution, etc. 2018
300 ## - PHYSICAL DESCRIPTION
Extent 123 P. :
Other physical details charts , facimiles ;
Dimensions 25cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Periodontology
520 ## - SUMMARY, ETC.
Summary, etc. This study was carried out to compare the clinical success rate of the dental implants that are placed with or without immediate loading in fresh extraction sockets versus healed bony sites. Twenty nine patients (16 females and 13 males with a mean age of 29.03 ± 3.39 years participated in this study and were divided into four groups. The first group (Group A) comprised of seven patients, one patient received 2 implants and the six other patients received a single implant immediately after extraction in fresh extraction sockets with immediate loading. The second group (Group B) comprised of eight patients who received implants immediately after extraction in fresh extraction sockets with delayed loading. The third group (Group C) comprised of six patients two of them received 2 implants and the rest received a single implant in healed bony sites with immediate loading. The fourth group (Group D) comprised of eight patients who received implants in healed bony sites with delayed loading. Immediate loading groups (A and C) received temporary acrylic crowns for 3-4 months which was then replaced with porcelain fused to metal as a final restoration. The patients were evaluated at 3 and 6 month intervals. Clinical criteria were survival rate, bleeding index, probing depth, gingival index and the mobility of the implant (Periotest values). Radiographic evaluation was performed using standardized radiographs to evaluate the surrounding bone at intervals immediately postoperative, 3 and 6 months after the implant placement
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Delayed implant
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Dental implants
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Immediate implant
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Ahmad Reda Abdulrahman ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Amr Ahmed Fouad Zahran ,
Relator term
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a>
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Shimaa
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.09.08.M.Sc.2018.Mo.E 01010110081617000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.09.08.M.Sc.2018.Mo.E 01020110081617000 22.09.2023 CD - Rom 81617.CD