header

Determination of some metal ions using carbon paste electrodes / (Record no. 81829)

MARC details
000 -LEADER
fixed length control field 02219cam a2200313 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 210823s2021 ua dh f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.12.08.M.Sc.2021.He.D
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Heba Aly Mohammad Marzouk
245 10 - TITLE STATEMENT
Title Determination of some metal ions using carbon paste electrodes /
Statement of responsibility, etc. Heba Aly Mohammad Marzouk ; Supervised Eman Yossri Frag , Marwa Elbadry Mohamed
246 15 - VARYING FORM OF TITLE
Title proper/short title تتقدير بعض أيونات العناصر بإستخدام أقطاب عجينة الكربون
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Heba Aly Mohammad Marzouk ,
Date of publication, distribution, etc. 2021
300 ## - PHYSICAL DESCRIPTION
Extent 72 P. :
Other physical details charts , facimiles ;
Dimensions 25cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - Cairo University - Faculty of Science - Department of Analytical Chemistry
520 ## - SUMMARY, ETC.
Summary, etc. In this paper, an effective, selective, and inexpensive Cr(III) ions modified carbon paste electrode (MCPE) based on benazepril (BNZ) was developed and described. It shows a good Nernstian slope of 19.20 + 0.39 mV decade-1 over a wide linear range of 8.0 {u00D7} 10-6{u2013} 1.0 {u00D7} 10-1 mol L-1 with a fast response time (10 s) and can be applied for measurements for at least 54 days with negligible change in results. The proposed sensor was pH-Independent in the range of 2.5{u2013}6.5 and showed an excellent selectivity towards Cr(III) ions over many other cations. The Cr(III)-BNZ surface interaction was investigated by using the energy dispersive X-ray analysis (EDX) and a scanning electron microscope (SEM). The proposed MCPE was completely validated according to the EURACHEM guidelines. Lastly, the proposed electrode efficiency for trace amount determination of Cr(III) ions in various food samples was examined, and the obtained results were compared with the results of the inductively coupled plasma-optical emission spectroscopy (ICP-OES)
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Chromium
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Modified CPE
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Sensor
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Eman Yossri Frag ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Marwa Elbadry Mohamed ,
Relator term
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Shimaa
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.12.08.M.Sc.2021.He.D 01010110083999000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.12.08.M.Sc.2021.He.D 01020110083999000 22.09.2023 CD - Rom 83999.CD