header

Effect of metal artifact reduction of cone beam computed tomography machine on accuracy of linear measurements of titanium dental implants : (Record no. 83781)

MARC details
000 -LEADER
fixed length control field 02977cam a2200325 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 220102s2021 ua dh f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level Ph.D
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.09.05.Ph.D.2021.Ka.E
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Karim Amir Albert Boutros
245 10 - TITLE STATEMENT
Title Effect of metal artifact reduction of cone beam computed tomography machine on accuracy of linear measurements of titanium dental implants :
Remainder of title A validity and reliabality study /
Statement of responsibility, etc. Karim Amir Albert Boutros ; Supervised Farid Medhat , Nashwa Salah , Islam Shawky Shaker
246 15 - VARYING FORM OF TITLE
Title proper/short title تاثير تقنية الحد من التشويش الناتج عن وجود معدن لجهاز التصوير المقطعى بالحاسوب مخروطى الشعاع على دقة القياسات الخطية للغرسات التيتانيوم :
Remainder of title دراسة صلاحية ومصداقية
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Karim Amir Albert Boutros ,
Date of publication, distribution, etc. 2021
300 ## - PHYSICAL DESCRIPTION
Extent 105 P. :
Other physical details charts , facsimiles ;
Dimensions 25cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (Ph.D.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Oral (Radiology and Diagnosis)
520 ## - SUMMARY, ETC.
Summary, etc. Aim: Beam hardening is considered highly common encountered artifacts in the CBCT scans. Metal artefacts can disrupt the original details of structures and objects in the radiograph that are adjacent to or near a highly attenuating object, and they can also project across the image field of view, resulting in inaccurate grey scale values for areas not immediately adjacent to the highly attenuating material.This study was planned to investigate the effect of metal artefact reduction (MAR) of cone beam computed tomography on the accuracy of implant linear measurements. Methodology: In this study eighteen patients with dental implants inserted in their jaws will be scanned by SOREDEX CRANEX® 3D cone beam computed tomography machine in two radiology centers. The resultant images will be reconstructed with and without metal artifact reduction (MAR) as a variable with other parameters being constant in all scans and the linear measurements acquired from the resultant images will be compared with the real measurements{u2019} length and width of titanium dental implant previously documented from the manufacturer information.Results: There was no statistically significant difference between implant length and width measurements scanned with SOREDEX CRANEX® 3D compared to the real implant measurements, however Implant width measurement error percentage with MAR showed statistically significantly lower median value than without MAR
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Accuracy
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Cone beam
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Metal artifact
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Farid Medhat ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Islam Shawky Shaker ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Nashwa Salah ,
Relator term
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Shimaa
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.09.05.Ph.D.2021.Ka.E 01010110085132000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.09.05.Ph.D.2021.Ka.E 01020110085132000 22.09.2023 CD - Rom 85132.CD