header
Local cover image
Local cover image
Image from OpenLibrary

Relationship between glenohumeral subluxation and hand dexterity in patients with stroke by Mariam Mohamed Khalifa; Prof. Dr. Mohamed Nabil El-Bahrawy, Prof.Dr. Ahmed Abdelalem, Prof.Dr. Rami Edward Asaad

By: Contributor(s): Material type: TextTextLanguage: English Summary language: English, Arabic Producer: 2023Description: 77 pages : illustrations ; 25 cm. + CDContent type:
  • text
Media type:
  • Unmediated
Carrier type:
  • volume
Other title:
  • العلاقة بین ملخ الكتف وبراعة اليد في مرضى السكتة الدماغية [Added title page title]
Subject(s): DDC classification:
  • 615.82
Available additional physical forms:
  • Issued also as CD
Dissertation note: Thesis (M.Sc.) -Cairo University, 2023. Summary: This study was conducted to investigate the relationship between glenohumeral subluxation and hand dexterity in patients with stroke. This study had been carried out on thirty patients from both sexes, previously diagnosed to have cerebrovascular accident, the duration of condition was more than 6 months. Their ages ranged from 45-65 years old. The patients were selected from Faculty of Physical Therapy-Cairo, University and Al-Kasr Alainy Hospital., Cairo, Egypt. Glenohumeral subluxation was assessed by X-ray and Finger Breadth test, hand dexterity was assessed by Purdue Pegboard Test. Data were collected and statistically analyzed. The results of the study showed significant differences between x-ray analysis scores and purdue pegboard scores, significant difference between the VAN scores and PPBT scores with no correlation between FMA and x-ray analysis scores.Summary: تم تقييم ملخ الكتف لجميع المشاركين باختبار FB وبالتصوير الشعاعي للكتف بالأشعة السينية وتقييم براعة اليد باستخدام PPBT ومقياس Fugl-Meyer لقياس وظائف الطرف العلوي الخاص بمرضى السكتة الدماغية. وجود ارتباط طردي ذو دلالة إحصائية بين قياسات الاشعة السينية لملخ الكتف ونتائج تقييم براعة اليد. وعدم وجود ارتباط احصائي بين مقياس Fugl-Meyer لوظائف الطرف العلوي وبين قياسات الاشعة السينية للكتف المصاب. أن ملخ الكتف له تأثير سلبي على جودة براعة اليد في مرضى السكتة الدماغية.
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Home library Call number Status Barcode
Thesis Thesis قاعة الرسائل الجامعية - الدور الاول المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.21.08.M.Sc.2023.Ma.R (Browse shelf(Opens below)) Not for loan 01010110088600000

Thesis (M.Sc.) -Cairo University, 2023.

Bibliography: pages 200-64. .

This study was conducted to investigate the relationship between glenohumeral subluxation and hand dexterity in patients with stroke. This study had been carried out on thirty patients from both sexes, previously diagnosed to have cerebrovascular accident, the duration of condition was more than 6 months. Their ages ranged from 45-65 years old. The patients were selected from Faculty of Physical Therapy-Cairo, University and Al-Kasr Alainy Hospital., Cairo, Egypt. Glenohumeral subluxation was assessed by X-ray and Finger Breadth test, hand dexterity was assessed by Purdue Pegboard Test. Data were collected and statistically analyzed.
The results of the study showed significant differences between x-ray analysis scores and purdue pegboard scores, significant difference between the VAN scores and PPBT scores with no correlation between FMA and x-ray analysis scores.

تم تقييم ملخ الكتف لجميع المشاركين باختبار FB وبالتصوير الشعاعي للكتف بالأشعة السينية وتقييم براعة اليد باستخدام PPBT ومقياس Fugl-Meyer لقياس وظائف الطرف العلوي الخاص بمرضى السكتة الدماغية. وجود ارتباط طردي ذو دلالة إحصائية بين قياسات الاشعة السينية لملخ الكتف ونتائج تقييم براعة اليد. وعدم وجود ارتباط احصائي بين مقياس Fugl-Meyer لوظائف الطرف العلوي وبين قياسات الاشعة السينية للكتف المصاب. أن ملخ الكتف له تأثير سلبي على جودة براعة اليد في مرضى السكتة الدماغية.

Issued also as CD

Text in English and abstract in Arabic & English.

There are no comments on this title.

to post a comment.

Click on an image to view it in the image viewer

Local cover image