Feasibility Of Patient- Specific Titanium Mesh Via A Transantral Approach For Repair Of Orbital Floor Fractures: A Case Series Study / By Aliaa khalaf Abd Ellatief Mohamed; Supervisors Assoc. Prof Dr. Yasmine Ahmed Nassar, Dr. Mona Samy Elhadidy

By: Contributor(s): Material type: TextTextLanguage: English Summary language: English, Arabic Producer: 2023Description: 74 pages : illustrations ; 25 cm. + CDContent type:
  • text
Media type:
  • Unmediated
Carrier type:
  • volume
Other title:
  • :اختبار فعالية استخدام شريحة خاصة بالمريض مصنعة بدقة الكمبيوتر لإصلاح كسور أرضية الحجاج عبر نهج عابر للمجرى الأنفي الغار دراسة سلسلة من الحالات دراسة سلسلة من الحالات [Added title page title]
Subject(s): DDC classification:
  • 617.605
Available additional physical forms:
  • Issued also as CD
Dissertation note: Thesis (M.Sc.) -Cairo University, 2023. Summary: This study was conducted to evaluate the feasibility of patient specific titanium mesh via trans-antral approach on correcting enophthalmos and orbital volume in patients with recent unilateral orbital floor fracture by means of clinical and radiographic findings. The present study was conducted on 7 male participants. The patients’ selection was done through the out-patient clinics in oral and maxillofacial surgery department of faculty of dentistry, Cairo university, Egypt. The clinical and radiographic parameters were observed, analyzed and carefully reported at different follow-up intervals (pre-operative, 1-day, 1-week, 1-month, 3-months and 1-year post-operatively). The study shows no differences between trans-antral intra-oral approach and traditional trans-cutaneous approaches using patient specific titanium mesh regarding enophthalmos correction and decreasing orbital volume, with superior results in decreasing intra-operative mesh modification and thereby shorter the surgery duration and higher contour accuracy and decreasing post-operative complication such as ectropion, entropion and hypertrophic scarring. Summary: أجريت هذه الدراسة لتقييم اختبار فعالية استخدام شريحة خاصة بالمريض مصنعة بدقة الكمبيوتر لإصلاح كسور أرضية الحجاج عبر نهج عابر للمجرى الأنفي (الغار) . أجريت الدراسة الحالية على 7 ذكور مشاركين. تم اختيار المرضى من خلال العيادات الخارجية في قسم جراحة الفم والوجه والفكين بكلية طب الفم والأسنان، جامعة القاهرة مصر. تمت ملاحظة النتائج السريرية والشعاعية وتحليلها والإبلاغ عنها بعناية في فترات متابعة مختلفة (قبل الجراحة، 1 يوم، 1 أسبوع، 1 شهر، 3 أشهر و1 سنة بعد الجراحة). أظهرت الدراسة عدم وجود فروق بين الطريقتين فيما يتعلق بتصحيح سقوط العين للداخل وتصحيح حجم التجويف المداري للعين، مع نتائج متفوقة في تقليل الحاجة الى تعديل الشريحة أثناء العملية وتقليل وقت العملية ودقة انحناء أعلى لصالح مجموعة الدراسة. نقر بأننا قد قرأنا العمل الحالي وأنه في رأينا مناسب تماما من حيث النطاق والجود كأطروحة نحو الإيفاء لمتطلبات درجة الماجستير في جراحة الفم والوجه والفكين
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Home library Call number Status Barcode
Thesis Thesis قاعة الرسائل الجامعية - الدور الاول المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.09.13.M.Sc.2023.Al.F. (Browse shelf(Opens below)) Not for loan 01010110089988000
Browsing المكتبة المركزبة الجديدة - جامعة القاهرة shelves Close shelf browser (Hides shelf browser)
No cover image available
No cover image available
No cover image available
No cover image available
No cover image available
No cover image available
No cover image available
Cai01.09.13.M.Sc.2023.Ah.C. A comparison of passive fit between an open tray conventional impression and an extra oral digital impression techniques for an all-on-6 maxillary framework : An Vitro Study / Cai01.09.13.M.Sc.2023.Ah.E Evaluation of primary stability and survival rate of implant with closed maxillary sinus lift in posterior maxilla using osseodensification technique (Densah Bur) versus conventional osteotome : A Randomized Clinical Trial / Cai01.09.13.M.Sc.2023.Al.B Bone marrow aspirate concentrate (BMAC) on 3D printed Polycaprolactone (PCL) scaffold for ridge augmentation of horizontal alveolar defects in aesthetic zone : Clinical case series study / Cai01.09.13.M.Sc.2023.Al.F. Feasibility Of Patient- Specific Titanium Mesh Via A Transantral Approach For Repair Of Orbital Floor Fractures: A Case Series Study / Cai01.09.13.M.Sc.2023.Al.P. Papilla index & pink esthetic score around customized vs standard healing abutment in immediate implant cases : A randomized controlled trial / Cai01.09.13.M.Sc.2023.Ha.C. A Comparison Of Passive Fit Between Conventional And Digital Impression Techniques For An All-On-6 Maxillary Framework : An Invitro Study / Cai01.09.13.M.Sc.2023.Ka.A Assessment of retention of ot equator smart box attachment system in mandibular implant-retained overdenture with angulated implant versus straight angled implan : An-in vitro study /

Thesis (M.Sc.) -Cairo University, 2023.

Bibliography: pages 69-72.

This study was conducted to evaluate the feasibility of patient specific titanium mesh via trans-antral approach on correcting enophthalmos and orbital volume in patients with recent unilateral orbital floor fracture by means of clinical and radiographic findings.
The present study was conducted on 7 male participants.
The patients’ selection was done through the out-patient clinics in oral and maxillofacial surgery department of faculty of dentistry, Cairo university, Egypt.
The clinical and radiographic parameters were observed, analyzed and carefully reported at different follow-up intervals (pre-operative, 1-day, 1-week, 1-month, 3-months and 1-year post-operatively).
The study shows no differences between trans-antral intra-oral approach and traditional trans-cutaneous approaches using patient specific titanium mesh regarding enophthalmos correction and decreasing orbital volume, with superior results in decreasing intra-operative mesh modification and thereby shorter the surgery duration and higher contour accuracy and decreasing post-operative complication such as ectropion, entropion and hypertrophic scarring.

أجريت هذه الدراسة لتقييم اختبار فعالية استخدام شريحة خاصة بالمريض مصنعة بدقة الكمبيوتر لإصلاح كسور أرضية الحجاج عبر نهج عابر للمجرى الأنفي (الغار) .
أجريت الدراسة الحالية على 7 ذكور مشاركين.
تم اختيار المرضى من خلال العيادات الخارجية في قسم جراحة الفم والوجه والفكين بكلية طب الفم والأسنان، جامعة القاهرة مصر.
تمت ملاحظة النتائج السريرية والشعاعية وتحليلها والإبلاغ عنها بعناية في فترات متابعة مختلفة (قبل الجراحة، 1 يوم، 1 أسبوع، 1 شهر، 3 أشهر و1 سنة بعد الجراحة).
أظهرت الدراسة عدم وجود فروق بين الطريقتين فيما يتعلق بتصحيح سقوط العين للداخل وتصحيح حجم التجويف المداري للعين، مع نتائج متفوقة في تقليل الحاجة الى تعديل الشريحة أثناء العملية وتقليل وقت العملية ودقة انحناء أعلى لصالح مجموعة الدراسة.