Evaluation of the efficacy of reciproc and revo - s in preparation of oval root canals using cone beam computed tomography / Mahmoud Mohamed Abdulbaky ; Supervised Hebatallah Mohamed Maged Elfar , Hani Samy Sadek
Material type: TextLanguage: English Publication details: Cairo : Mahmoud Mohamed Abdulbaky , 2013Description: 106 Leaves : photographs ; 30cmOther title:- فى تحضير قنوات الجذور البيضاوى باستخدام جهاز الأشعة المخروطى receiproc revo - s تقييم فعالية انظمة النيكل تايتانيوم من نوع [Added title page title]
- Issued also as CD
Item type | Current library | Home library | Call number | Copy number | Status | Date due | Barcode | |
---|---|---|---|---|---|---|---|---|
Thesis | قاعة الرسائل الجامعية - الدور الاول | المكتبة المركزبة الجديدة - جامعة القاهرة | Cai01.09.02.M.Sc.2013.Ma.E (Browse shelf(Opens below)) | Not for loan | 01010110065661000 | |||
CD - Rom | مخـــزن الرســائل الجـــامعية - البدروم | المكتبة المركزبة الجديدة - جامعة القاهرة | Cai01.09.02.M.Sc.2013.Ma.E (Browse shelf(Opens below)) | 65661.CD | Not for loan | 01020110065661000 |
Browsing المكتبة المركزبة الجديدة - جامعة القاهرة shelves Close shelf browser (Hides shelf browser)
Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Endodontics
To evaluate the efficacy of revo - S and reciproc R40 NiTi files in preparation of oval root canals using cone beam computed Tomography (CBCT). Forty extracted single rooted premolars were divided into 2 groups (n = 20). Group 1 (R - S) were prepared with revo - S up to size #40 / .06. Group 2 (R40) were prepared to the same size with a single file R40. Pre - and post-instrumentation CBCT scanning was done. Calculated parameters were: increase ({u1EB0}) in canal volume and surface area. Transportation, centering ability, and untouched canal areas were tested at 3, 6, 9 mms axial sections. Statistical analyses were made using Mann-Whitney U and Friedman{u2019}s test (P {u2264} 0.05). Significant increase in {u1EB0} volume (P = .000 and P = .003 for R - S and R40 respectively) and {uF044} surface area (P = 0.048 and P = 0.038 for R - S and R40 respectively) was found for both instrumentation kinematics with no significant differences between them. Canals{u2019} transportation and decreased centering ratio were detected in both groups at all tested levels with insignificant smaller values in the M - D direction. Exception was found at 9mm level where a significantly highest transportation was found in R - S group P = 0.022
Issued also as CD
There are no comments on this title.