header
Image from OpenLibrary

IOL master optical biometry versus conventional ultrasound biometry in intraocular lens power calculations in various types of cataract / Soheir Hozayen Gaballa ; Supervised Karim Adly Raafat , Nahla Borhan Abohussein , Riham Samy Hanafy Mahmoud Allam

By: Contributor(s): Material type: TextTextLanguage: English Publication details: Cairo : Soheir Hozayen Gaballa , 2014Description: 71P. : charts , facsimiles ; 25cmOther title:
  • مقارنة بين استخدام مقياس العدسة الضوئى ومقياس العدسة الفوق صوتى فى حساب قوة العدسة الداخلية للعين فى أنواع مختلفة من المياة البيضاء [Added title page title]
Subject(s): Available additional physical forms:
  • Issued also as CD
Dissertation note: Thesis (M.Sc.) - Cairo University - Faculty of Medicine - Department of Ophthalmology Summary: This study discusses the IOL power calculation and hence the post operative refractive error through comparison between the use of IOL master and A- scan biometry in measuring the axial length of the eye. This comparison has been done in myopic eyes, silicone filled eyes, and eyes with nuclear cataract grade I&II. This study concluded that The IOL Master has simplified considerably the process of ocular biometry. It is a non-contact technique, which does not require use of topical anesthesia, thus providing comfort to the patient and preventing corneal abrasions and the transmission of infections. Furthermore it has greater accuracy than ultrasound biometry because it measures the ocular AXL along the visual axis, as the patient fixates at the measurement beam, whereas during ultrasound biometry a misalignment between the measured axis and the visual axis may result in erroneously longer AXL measurements. This is especially important in eyes with posterior pole staphyloma because of the more precise localization of the fovea. In addition it is easier to master its use
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Home library Call number Copy number Status Date due Barcode
Thesis Thesis قاعة الرسائل الجامعية - الدور الاول المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.11.24.M.Sc.2014.So.I (Browse shelf(Opens below)) Not for loan 01010110066480000
CD - Rom CD - Rom مخـــزن الرســائل الجـــامعية - البدروم المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.11.24.M.Sc.2014.So.I (Browse shelf(Opens below)) 66480.CD Not for loan 01020110066480000
Browsing المكتبة المركزبة الجديدة - جامعة القاهرة shelves Close shelf browser (Hides shelf browser)
No cover image available
No cover image available
No cover image available
No cover image available
No cover image available
No cover image available
No cover image available
Cai01.11.24.M.Sc.2014.Sa.S Subconjunctival bevacizumab in corneal neovascularization / Cai01.11.24.M.Sc.2014.So.C Comparative study between average retinal nerve fiber layer thickness in superior and inferior quadrants in 20 years versus 50 years old population using optical coherence tomography / Cai01.11.24.M.Sc.2014.So.C Comparative study between average retinal nerve fiber layer thickness in superior and inferior quadrants in 20 years versus 50 years old population using optical coherence tomography / Cai01.11.24.M.Sc.2014.So.I IOL master optical biometry versus conventional ultrasound biometry in intraocular lens power calculations in various types of cataract / Cai01.11.24.M.Sc.2014.So.I IOL master optical biometry versus conventional ultrasound biometry in intraocular lens power calculations in various types of cataract / Cai01.11.24.M.Sc.2015.Am.A Anterior segment optical coherence tomography to assess accuracy of the flap after laser insitu keratomileusis : A comparative study between femtolasik and m2 microkeratome / Cai01.11.24.M.Sc.2015.Am.A Anterior segment optical coherence tomography to assess accuracy of the flap after laser insitu keratomileusis : A comparative study between femtolasik and m2 microkeratome /

Thesis (M.Sc.) - Cairo University - Faculty of Medicine - Department of Ophthalmology

This study discusses the IOL power calculation and hence the post operative refractive error through comparison between the use of IOL master and A- scan biometry in measuring the axial length of the eye. This comparison has been done in myopic eyes, silicone filled eyes, and eyes with nuclear cataract grade I&II. This study concluded that The IOL Master has simplified considerably the process of ocular biometry. It is a non-contact technique, which does not require use of topical anesthesia, thus providing comfort to the patient and preventing corneal abrasions and the transmission of infections. Furthermore it has greater accuracy than ultrasound biometry because it measures the ocular AXL along the visual axis, as the patient fixates at the measurement beam, whereas during ultrasound biometry a misalignment between the measured axis and the visual axis may result in erroneously longer AXL measurements. This is especially important in eyes with posterior pole staphyloma because of the more precise localization of the fovea. In addition it is easier to master its use

Issued also as CD

There are no comments on this title.

to post a comment.