Effect of three different implant diameter on the stress induced on supporting structure bone in implant supported over denture : Finite element study / Osama Ahmed Gaballah ; Supervised Hamdi AboElfotouh , Ahmed Emad Fayyad
Material type:
- تأثير ثلاثه غرسات مختلفة القطر على الاجهاد المتولد على العظم فى الاطقم الفوقيه المدعمة بغرسات [Added title page title]
- Issued also as CD
Item type | Current library | Home library | Call number | Copy number | Status | Barcode | |
---|---|---|---|---|---|---|---|
![]() |
قاعة الرسائل الجامعية - الدور الاول | المكتبة المركزبة الجديدة - جامعة القاهرة | Cai01.09.09.M.Sc.2015.Os.E (Browse shelf(Opens below)) | Not for loan | 01010110068757000 | ||
![]() |
مخـــزن الرســائل الجـــامعية - البدروم | المكتبة المركزبة الجديدة - جامعة القاهرة | Cai01.09.09.M.Sc.2015.Os.E (Browse shelf(Opens below)) | 68757.CD | Not for loan | 01020110068757000 |
Browsing المكتبة المركزبة الجديدة - جامعة القاهرة shelves Close shelf browser (Hides shelf browser)
Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Prosthodontics
The present study was conducted to evaluate the stress patterns induced in implants and bone surrounding implants in mandibular overdenture with three different diameters using three dimensional finite element analysis. Three different implant diameters were used. A computerized tomographic image was obtained. Three dimensional geometrical models were constructed using data from the computerized tomographic image into solid works program. The implants were virtually installed in the molar and canine region with diameter 2.8mm, 3.7 and 4.8mm. The material properties for each material were identified in the program. Vertical and oblique loads were applied for each model. The models were restrained at the inferior border to avoid total body displacement. All models were meshed and analyzed using a three dimensional finite element iterative solving method for stress analysis under vertical and oblique loading. The maximal Von Misses stresses were recorded and computed. The maximum stresses were recorded with 2.8 mm diameter (mini dental implant), while the least stresses were recorded with 4.8 mm diameter. These findings may be attributed to the different implant diameter. It was found that stresses had been increased due to the decrease in implant diameter. The stress values induced in the peri-implant bone due to the oblique load were greater than those induced by the vertical load
Issued also as CD
There are no comments on this title.