Diagnostic accuracy of cone beam computed tomography versus low dose computed tomography : In vitro study / Hagar Mohamed Elsarawy ; Supervised Hoda Abdelkader Saleh , Sherouk Hassan Ali Khalifa

By: Contributor(s): Material type: TextTextLanguage: English Publication details: Cairo : Hagar Mohamed Elsarawy , 2015Description: 142 P. : facsimiles ; 25cmOther title:
  • الدقة التشخيصية للأشعة المقطعية بالحاسوب مخروطية الشعاع مقابل الأشعة المقطعية بالحاسوب ذات الجرعة الاشعاعية القليلة : دراسة مختبرية [Added title page title]
Subject(s): Online resources: Available additional physical forms:
  • Issued also as CD
Dissertation note: Thesis (Ph.D.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Oral and Maxillofacial Surgery Summary: This study was designed to compare the accuracy of low dose CT versus CBCT in assessment of the various maxillofacial linear measurements. Methods: 8 skulls were included in this study and 11 linear skull measurements were selected. Direct bone measurements were obtained using digital caliber then skulls were imaged once using CBCT standard protocol and 3 times with 16 slices MDCT using three low dose protocols with reduced mAs values (40, 50, 60 mAs). Mean absolute error for each whole protocol was obtained and the degree of over and underestimation for each protocol was recorded. Results: or CBCT protocol the mean absolute error was 0.167 ± 0.6461mm while for the MDCT protocols it was 0.632 ± 0.9803, 0.320 ± 0.8393, 0.166 ± 0.803mm For the first, second and third protocol respectively. First and second protocols showed a tendency for overestimation while the third MDCT protocol and CBCT protocol showed a tendency for underestimation. But all were within the range of 1mm. Conclusions: Low dose MDCT accuracy is less than that of CBCT but the difference between the two techniques is still not significant in some protocols
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Home library Call number Copy number Status Barcode
Thesis Thesis قاعة الرسائل الجامعية - الدور الاول المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.09.13.Ph.D.2015.Ha.D (Browse shelf(Opens below)) Not for loan 01010110071101000
CD - Rom CD - Rom مخـــزن الرســائل الجـــامعية - البدروم المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.09.13.Ph.D.2015.Ha.D (Browse shelf(Opens below)) 71101.CD Not for loan 01020110071101000
Browsing المكتبة المركزبة الجديدة - جامعة القاهرة shelves Close shelf browser (Hides shelf browser)
No cover image available
No cover image available
No cover image available
No cover image available
No cover image available
No cover image available
No cover image available
Cai01.09.13.Ph.D.2015.En.E Effect of voxel size and field of view on the accuracy of cone beam computed tomographic assessment of alveolar bone loss in periodontal defects : In vitro study / Cai01.09.13.Ph.D.2015.Es.C Comparison between three-dimensional and standard miniplates in the fixation of mandibular angle fractures : Randomized, controlled clinical trial / Cai01.09.13.Ph.D.2015.Es.C Comparison between three-dimensional and standard miniplates in the fixation of mandibular angle fractures : Randomized, controlled clinical trial / Cai01.09.13.Ph.D.2015.Ha.D Diagnostic accuracy of cone beam computed tomography versus low dose computed tomography : In vitro study / Cai01.09.13.Ph.D.2015.Ha.D Diagnostic accuracy of cone beam computed tomography versus low dose computed tomography : In vitro study / Cai01.09.13.Ph.D.2015.Mo.C Computer-guided mandibular segmental resection and immediate reconstruction using patient specific titanium devices versus conventional techniques = Randomized Control Clinical Tria l = الاستئصال القطعي للفك السفلي الموجه بالكومبيوتر و اعاده البناء المباشره باستخدام جهاز تيتانيوم خاص بالمريض في مقابل استخدام التقنيات التقليديه : تجربه سريريه للتحكم الجزافي / Cai01.09.13.Ph.D.2015.Mo.C Computer-guided mandibular segmental resection and immediate reconstruction using patient specific titanium devices versus conventional techniques = Randomized Control Clinical Tria l = الاستئصال القطعي للفك السفلي الموجه بالكومبيوتر و اعاده البناء المباشره باستخدام جهاز تيتانيوم خاص بالمريض في مقابل استخدام التقنيات التقليديه : تجربه سريريه للتحكم الجزافي /

Thesis (Ph.D.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Oral and Maxillofacial Surgery

This study was designed to compare the accuracy of low dose CT versus CBCT in assessment of the various maxillofacial linear measurements. Methods: 8 skulls were included in this study and 11 linear skull measurements were selected. Direct bone measurements were obtained using digital caliber then skulls were imaged once using CBCT standard protocol and 3 times with 16 slices MDCT using three low dose protocols with reduced mAs values (40, 50, 60 mAs). Mean absolute error for each whole protocol was obtained and the degree of over and underestimation for each protocol was recorded. Results: or CBCT protocol the mean absolute error was 0.167 ± 0.6461mm while for the MDCT protocols it was 0.632 ± 0.9803, 0.320 ± 0.8393, 0.166 ± 0.803mm For the first, second and third protocol respectively. First and second protocols showed a tendency for overestimation while the third MDCT protocol and CBCT protocol showed a tendency for underestimation. But all were within the range of 1mm. Conclusions: Low dose MDCT accuracy is less than that of CBCT but the difference between the two techniques is still not significant in some protocols