The effect of different abutment materials on the fracture resistance and stress distribution of implant supported fixed partial denture : In vitro study = تأثير اختلاف المواد الداعمة للبنية الفوقية المرممة للغرسة على مقاومة الكسر و توزيع الضغط : دراسة فى المختبر / Mohamed Mostafa Mohamed ; Supervised Omaima Elmahallawi , Gihan Elnagar

By: Contributor(s): Material type: TextTextLanguage: English Publication details: Cairo : Mohamed Mostafa Mohamed , 2017Description: 144 P. : charts , photographs ; 25cmOther title:
  • تأثير اختلاف المواد الداعمة للبنية الفوقية المرممة للغرسة على مقاومة الكسر و توزيع الضغط : دراسة فى المختبر [Added title page title]
Subject(s): Online resources: Available additional physical forms:
  • Issued also as CD
Dissertation note: Thesis (Ph.D.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Prosthodontics Summary: Successful long-term results of dental implants have led to an increase in their usage in many clinical situations. Since the introduction of osseo-integrated implants for the rehabilitation of the partially edentulous patient, a tremendous awareness and subsequent demand have arisen in the field resulting in implant supported fixed prosthesis being widely accepted as an alternative to conventional removable prosthesis. However, some clinical studies have reported variable rates of failure. Biomechanical factors and stress distribution around implant supported FPDs are some of the prime factors leading to failure of implant supported. The current study evaluated the effect of different abutment materials titanium and zirconia with different bone density (D2 and D3) on the stress distribution and fracture resistance of implant supported FPD. The relative effect of the two different abutment materials were compared using mechanical loading test together with strain gauge analysis. The following materials were used in the current study: 1. Zimmer dental Implant fixture. 2. Zimmer dental implant abutment.(titanium and zirconia) 3. in Coris TZI medi block 4. Provicol C temporary cement. 5. Unsaturated epoxy resin (cancellous bone). 6. Saturated epoxy resin (compact bone). Summary and conclusion 7. Electrical resistance strain gauges. Eight implants were fixed in four anatomically correct D2 and D3 bone density models in order to stimulate restoring posterior missing second premolar, first molar and second molar
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Home library Call number Copy number Status Barcode
Thesis Thesis قاعة الرسائل الجامعية - الدور الاول المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.09.09.Ph.D.2017.Mo.E (Browse shelf(Opens below)) Not for loan 01010110074601000
CD - Rom CD - Rom مخـــزن الرســائل الجـــامعية - البدروم المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.09.09.Ph.D.2017.Mo.E (Browse shelf(Opens below)) 74601.CD Not for loan 01020110074601000
Browsing المكتبة المركزبة الجديدة - جامعة القاهرة shelves Close shelf browser (Hides shelf browser)
No cover image available
No cover image available
No cover image available
No cover image available
No cover image available
No cover image available
No cover image available
Cai01.09.09.Ph.D.2017.Ma.E Evaluation of fracture resistance and vertical marginal gap of hybrid versus pressable ceramic laminate veneers : In vitro study / Cai01.09.09.Ph.D.2017.Ma.I Implant stability in single implant versus two implants retained mandibular over denture in completely edentulous patients : A Randomized controlled clinical trial / Cai01.09.09.Ph.D.2017.Ma.I Implant stability in single implant versus two implants retained mandibular over denture in completely edentulous patients : A Randomized controlled clinical trial / Cai01.09.09.Ph.D.2017.Mo.E The effect of different abutment materials on the fracture resistance and stress distribution of implant supported fixed partial denture : In vitro study = تأثير اختلاف المواد الداعمة للبنية الفوقية المرممة للغرسة على مقاومة الكسر و توزيع الضغط : دراسة فى المختبر / Cai01.09.09.Ph.D.2017.Mo.E The effect of different abutment materials on the fracture resistance and stress distribution of implant supported fixed partial denture : In vitro study = تأثير اختلاف المواد الداعمة للبنية الفوقية المرممة للغرسة على مقاومة الكسر و توزيع الضغط : دراسة فى المختبر / Cai01.09.09.Ph.D.2017.Mo.E Evaluation of patients satisfaction of obturator with attachment versus conventional obturator in treatment of unilateral maxillectomy : A randomized clinical trial / Cai01.09.09.Ph.D.2017.Mo.E Evaluation of patients satisfaction of obturator with attachment versus conventional obturator in treatment of unilateral maxillectomy : A randomized clinical trial /

Thesis (Ph.D.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Prosthodontics

Successful long-term results of dental implants have led to an increase in their usage in many clinical situations. Since the introduction of osseo-integrated implants for the rehabilitation of the partially edentulous patient, a tremendous awareness and subsequent demand have arisen in the field resulting in implant supported fixed prosthesis being widely accepted as an alternative to conventional removable prosthesis. However, some clinical studies have reported variable rates of failure. Biomechanical factors and stress distribution around implant supported FPDs are some of the prime factors leading to failure of implant supported. The current study evaluated the effect of different abutment materials titanium and zirconia with different bone density (D2 and D3) on the stress distribution and fracture resistance of implant supported FPD. The relative effect of the two different abutment materials were compared using mechanical loading test together with strain gauge analysis. The following materials were used in the current study: 1. Zimmer dental Implant fixture. 2. Zimmer dental implant abutment.(titanium and zirconia) 3. in Coris TZI medi block 4. Provicol C temporary cement. 5. Unsaturated epoxy resin (cancellous bone). 6. Saturated epoxy resin (compact bone). Summary and conclusion 7. Electrical resistance strain gauges. Eight implants were fixed in four anatomically correct D2 and D3 bone density models in order to stimulate restoring posterior missing second premolar, first molar and second molar

Issued also as CD

There are no comments on this title.

to post a comment.

Click on an image to view it in the image viewer

Local cover image