Assessment of the radiation dose in a medical linear accelerator using a simulation model and experimental verification / Ahmed Medhat Fahmy Moustafa ; Supervised Hassan Fathy Ibrahim , Ehab Marouf Attalla

By: Contributor(s): Material type: TextTextLanguage: English Publication details: Cairo : Ahmed Medhat Fahmy Moustafa , 2017Description: 178 P. : charts , facsimiles ; 25cmOther title:
  • تقييم الجرعة الاشعاعية في الدعجل الخطي الطبي باستخدام نموذج للمحاكاة والتأكد التجريبي [Added title page title]
Subject(s): Online resources: Available additional physical forms:
  • Issued also as CD
Dissertation note: Thesis (M.Sc.) - Cairo University - Faculty of Science - Department of Physics Summary: This research aims to investigate the use of the Monte Carlo (MC) simulations (Geant4/GATE) to estimate the radiation doses for different field sizes at the isocenter from a medical linac. A water phantom is irradiated by using a 6 MV photon beam delivered by Siemens ONCOR linac. The percent depth doses and dose profiles at different depths are measured using two types of ionization chamber, then compared with the MC calculated data. The comparisons show satisfactory agreement with gamma index passing rates from 63.15% to 98.87%, therefore, MC simulations can be considered adequate for the assessment of the radiation doses from any medical linac
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Home library Call number Copy number Status Barcode
Thesis Thesis قاعة الرسائل الجامعية - الدور الاول المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.12.20.M.Sc.2017.Ah.A (Browse shelf(Opens below)) Not for loan 01010110075748000
CD - Rom CD - Rom مخـــزن الرســائل الجـــامعية - البدروم المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.12.20.M.Sc.2017.Ah.A (Browse shelf(Opens below)) 75748.CD Not for loan 01020110075748000

Thesis (M.Sc.) - Cairo University - Faculty of Science - Department of Physics

This research aims to investigate the use of the Monte Carlo (MC) simulations (Geant4/GATE) to estimate the radiation doses for different field sizes at the isocenter from a medical linac. A water phantom is irradiated by using a 6 MV photon beam delivered by Siemens ONCOR linac. The percent depth doses and dose profiles at different depths are measured using two types of ionization chamber, then compared with the MC calculated data. The comparisons show satisfactory agreement with gamma index passing rates from 63.15% to 98.87%, therefore, MC simulations can be considered adequate for the assessment of the radiation doses from any medical linac