header
Local cover image
Local cover image
Image from OpenLibrary

Comparison between two different techniques of manufacturing the surgical guides on accuracy of implant placement in completely edentulous patients using CBCT : Randomized Clinical Trial / Belal Ahmed Mohammed Mohammed ; Supervised Amal Rekaby Taha , Azza Farahat

By: Contributor(s): Material type: TextTextLanguage: English Publication details: Cairo : Belal Ahmed Mohammed Mohammed , 2018Description: 82 P. : charts , facsimiles , photoghrahs ; 25cmOther title:
  • دراسه مقارنة بين تقنيتين مختلفتين لتصنيع الأدله الجراحيه على دقة وضع الغرسات السنيه في حالات الفقد الكلى للأسنان باستخدام الأشعه المقطعيه المخروطيه [Added title page title]
Subject(s): Online resources: Available additional physical forms:
  • Issued also as CD
Dissertation note: Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Prosthodontics Summary: Background : Recently, computed tomography (CT) has been introduced for pre-surgical implant planning. Prosthetically driven implant placement using computer software may ensure precise placement and predictable prosthetic outcomes. Stereolithography and selective laser sintering had become a favorable option for fabricating surgical guides. Purpose : To compare between laser sintering & stereolithiographgic techniques for manufacturing the surgical guides on the accuracy of implants{u2019} placement in completely edentulous patients using CBCT. Material and methods : Pre operative CBCT scanning were made for the patients; while they were wearing radiographic template. After planning of the surgical guide on software, printing with either stereolithography or selective laser sintering according to the group studied. Two implants were installed in the mandibular canine-premolar areas following computer aided surgical guides. Another post-operative CBCT scan was made for the patients while wearing the same radiographic template. Superimposition of the pre-operative CBCT (virtual planning) and the postoperative CBCT after implants insertion was made
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Home library Call number Copy number Status Barcode
Thesis Thesis قاعة الرسائل الجامعية - الدور الاول المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.09.09.M.Sc.2018.Be.C (Browse shelf(Opens below)) Not for loan 01010110078428000
CD - Rom CD - Rom مخـــزن الرســائل الجـــامعية - البدروم المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.09.09.M.Sc.2018.Be.C (Browse shelf(Opens below)) 78428.CD Not for loan 01020110078428000
Browsing المكتبة المركزبة الجديدة - جامعة القاهرة shelves Close shelf browser (Hides shelf browser)
No cover image available
No cover image available
No cover image available
No cover image available
No cover image available
No cover image available
No cover image available
Cai01.09.09.M.Sc.2018.Ba.M Marginal integrity of cemented hybrid ceramic(cerasmart) versus zirconia reinforced lithium disilicate ceramic (vita suprinity) occlusal veneers under cyclic loading : In-vitro study / Cai01.09.09.M.Sc.2018.Ba.M Marginal integrity of cemented hybrid ceramic(cerasmart) versus zirconia reinforced lithium disilicate ceramic (vita suprinity) occlusal veneers under cyclic loading : In-vitro study / Cai01.09.09.M.Sc.2018.Be.C Comparison between two different techniques of manufacturing the surgical guides on accuracy of implant placement in completely edentulous patients using CBCT : Randomized Clinical Trial / Cai01.09.09.M.Sc.2018.Be.C Comparison between two different techniques of manufacturing the surgical guides on accuracy of implant placement in completely edentulous patients using CBCT : Randomized Clinical Trial / Cai01.09.09.M.Sc.2018.Bi.E Efficacy of gender on the width-length ratio of maxillary anterior teeth in an Egyptian population and establishment of a guideline for esthetical accepted ratio of teeth dimensions to gum exposure / Cai01.09.09.M.Sc.2018.Bi.E Efficacy of gender on the width-length ratio of maxillary anterior teeth in an Egyptian population and establishment of a guideline for esthetical accepted ratio of teeth dimensions to gum exposure / Cai01.09.09.M.Sc.2018.Di.E Effect of resin cement shades & thickness of zirconia reinforced lithium disilicate ceramics (vita suprinity) on the optical properties using dark background compared to lithium disilicate glass ceramics : An in vitro study /

Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Prosthodontics

Background : Recently, computed tomography (CT) has been introduced for pre-surgical implant planning. Prosthetically driven implant placement using computer software may ensure precise placement and predictable prosthetic outcomes. Stereolithography and selective laser sintering had become a favorable option for fabricating surgical guides. Purpose : To compare between laser sintering & stereolithiographgic techniques for manufacturing the surgical guides on the accuracy of implants{u2019} placement in completely edentulous patients using CBCT. Material and methods : Pre operative CBCT scanning were made for the patients; while they were wearing radiographic template. After planning of the surgical guide on software, printing with either stereolithography or selective laser sintering according to the group studied. Two implants were installed in the mandibular canine-premolar areas following computer aided surgical guides. Another post-operative CBCT scan was made for the patients while wearing the same radiographic template. Superimposition of the pre-operative CBCT (virtual planning) and the postoperative CBCT after implants insertion was made

Issued also as CD

There are no comments on this title.

to post a comment.

Click on an image to view it in the image viewer

Local cover image