Evaluation of implant stability after application of platelet rich fibrin in mandibular posterior ridge splitting and immediate implant placement versus xenograft application : Randomized clinical trial / Shymaa Maghawry Ibrahim ; Supervised Elzahraa Fatma Elbagoury , Tarek Elghareeb
Material type:
- تقييم ثبات الغرسة بعد استعمال الفيبرين الغنى بالصفائح الدموية فى تقسيم الحافة السنخية للفك السفلى مع الوضع الفورى للغرسة مقابل استعمال رقعة عظمية حيوانية المصدر : تجربة اكلينيكية عشوائية [Added title page title]
- Issued also as CD
Item type | Current library | Home library | Call number | Copy number | Status | Barcode | |
---|---|---|---|---|---|---|---|
![]() |
قاعة الرسائل الجامعية - الدور الاول | المكتبة المركزبة الجديدة - جامعة القاهرة | Cai01.09.13.Ph.D.2019.Sh.E (Browse shelf(Opens below)) | Not for loan | 01010110080614000 | ||
![]() |
مخـــزن الرســائل الجـــامعية - البدروم | المكتبة المركزبة الجديدة - جامعة القاهرة | Cai01.09.13.Ph.D.2019.Sh.E (Browse shelf(Opens below)) | 80614.CD | Not for loan | 01020110080614000 |
Browsing المكتبة المركزبة الجديدة - جامعة القاهرة shelves Close shelf browser (Hides shelf browser)
Thesis (Ph.D.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Oral and Maxillofacial Surgery
Aim of the Study: The purpose of this study aimed to answer a clinical question whether the use of platelet rich fibrin after ridge splitting with simultaneous implant placement will enhance implant stability in comparison with xenograft or not. Materials and Methods: Sixteen patients were divided into 2 equal groups (Group I & Group II). Patients in both groups underwent surgical ridge splitting for narrow edentulous posterior mandibular ridge with simultaneous implant placement. In Group I, platelet rich fibrin used as a graft material around the implant in between buccal and lingual cortices. In Group II, Tutogen ® xenograft used as a graft material around the implant in between buccal and lingual cortices. Each patient was assessed for implant stability and relative bone density around the implant. Implant stability measured by Osstell TM by means of resonance frequency analysis (RFA) which was recoded as Implant Stability Quotient (ISQ) values first intraoperative then at intervals 3 months, 6months and 9 months postoperatively. However, the relative bone density has been evaluated by cone beam computed tomography (CBCT) immediate post-operative and 6 months later. All results were statistically analyzed
Issued also as CD
There are no comments on this title.