Clinical evaluation of the effect of low speed drilling versus conventional drilling technique on crestal bone level in maxilla : A randomized controlled clinical trial / Islam Atef Mohamed Abdelrazik Kandil ; Supervised Hani Mahmoud Essam Elnahass , Karim Mohamed Fawzy Elsayed
Material type:
- مستوى على التقليدية الحفر تقنية مقابل الحفر سرعة انخفاض للتأثير السريرى التقييم العلوى الفك فى القشرى العظم [Added title page title]
- Issued also as CD
Item type | Current library | Home library | Call number | Copy number | Status | Barcode | |
---|---|---|---|---|---|---|---|
![]() |
قاعة الرسائل الجامعية - الدور الاول | المكتبة المركزبة الجديدة - جامعة القاهرة | Cai01.09.09.M.Sc.2019.Is.C (Browse shelf(Opens below)) | Not for loan | 01010110080622000 | ||
![]() |
مخـــزن الرســائل الجـــامعية - البدروم | المكتبة المركزبة الجديدة - جامعة القاهرة | Cai01.09.09.M.Sc.2019.Is.C (Browse shelf(Opens below)) | 80622.CD | Not for loan | 01020110080622000 |
Browsing المكتبة المركزبة الجديدة - جامعة القاهرة shelves Close shelf browser (Hides shelf browser)
Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Prosthodontics
Aim: The aim of the present study was to evaluate the efficiency of low versus conventional speed drilling regarding the amount of crestal bone loss, bone density values, implant survival, implant stability, Visual Analogue Scale score and patients{u2019} satisfaction over 6 months follow up, following implant placement in maxillary edentulous ridge. Materials and methods: The present study is a randomized clinical trial conducted on 12 patients to evaluate the amount of crestal bone loss , density values, implant survival ,implant stability ,VAS score and patient satisfaction over 6 months follow up, following implant placement in maxillary edentulous ridge at low speed drilling without irrigation versus conventional drilling speed technique.Classical implant placement without any bone augmentation was the technique used in both groups. All patients were followed up clinically and radiographically for 6 months. Radiographic evaluation involved digital radiograph immediately after implant insertion, three months and six months postoperatively to evaluate crestal bone loss and bone density changes. Resonance frequency analysis to measure implant stability using Osstell device was performed immediately after implant insertion, three months postoperative at time of implant exposure and six months postoperative
Issued also as CD
There are no comments on this title.