Power system operation in the presence of flexible prosumers considering system congestion / Mayar Mohsen Mostafa Madboly ; Supervised Mohamed Salah Elsobki , Amgad Amin Eldeib
Material type: TextLanguage: English Publication details: Cairo : Mayar Mohsen Mostafa Madboly , 2021Description: 126 P. : charts ; 30cmOther title:- التشغيل الأمثل لنظم القوى الكهربية فى وجود الأحمال المرنة وأثناء اختناقات النظام [Added title page title]
- Issued also as CD
Item type | Current library | Home library | Call number | Copy number | Status | Date due | Barcode | |
---|---|---|---|---|---|---|---|---|
Thesis | قاعة الرسائل الجامعية - الدور الاول | المكتبة المركزبة الجديدة - جامعة القاهرة | Cai01.13.07.M.Sc.2021.Ma.P (Browse shelf(Opens below)) | Not for loan | 01010110084485000 | |||
CD - Rom | مخـــزن الرســائل الجـــامعية - البدروم | المكتبة المركزبة الجديدة - جامعة القاهرة | Cai01.13.07.M.Sc.2021.Ma.P (Browse shelf(Opens below)) | 84485.CD | Not for loan | 01020110084485000 |
Browsing المكتبة المركزبة الجديدة - جامعة القاهرة shelves Close shelf browser (Hides shelf browser)
No cover image available | No cover image available | No cover image available | No cover image available | No cover image available | No cover image available | No cover image available | ||
Cai01.13.07.M.Sc.2021.Ma.E Evaluation of adaptive control techniques in power system stabilization / | Cai01.13.07.M.Sc.2021.Ma.E Evaluation of adaptive control techniques in power system stabilization / | Cai01.13.07.M.Sc.2021.Ma.P Power system operation in the presence of flexible prosumers considering system congestion / | Cai01.13.07.M.Sc.2021.Ma.P Power system operation in the presence of flexible prosumers considering system congestion / | Cai01.13.07.M.Sc.2021.Mi.P Powering poultry farm using biomass and solar energy / | Cai01.13.07.M.Sc.2021.Mi.P Powering poultry farm using biomass and solar energy / | Cai01.13.07.M.Sc.2021.Mo.D Design and implementation of fuzzy machine learning based controller formaximum power point tracking of a PV farm system / |
Thesis (M.Sc.) - Cairo University - Faculty of Engineering - Department of Electrical Power and Machines
In this thesis, the optimal operation of the power system is studied using different objective functions: minimum total generation cost, minimum active power losses, minimum specific generation cost, minimum average energy cost. The effect of congestion on the voltage and reactive power output as well as the system performance is analyzed. The system performance is assessed through some key performance indices. Two IEEE benchmark systems which are IEEE 5-bus and 14-bus systems were used to test the formulations and algorithms. The model also includes variable loads and prosumers whose presence proved to be effective in dealing with power system congestion.The use of flexible loads and prosumers benefited the power system by reducing the system costs and losses. Additionally, the voltage profile of the system was enhanced
Issued also as CD
There are no comments on this title.