Ionising radiation dose calculation for the realse of I¹³¹ during accident conditions for materials test reactor / Mahmoud Ramadan Mohamed Mahmoud Aboeross ; Supervised Esmat Hanem Amin , Abdallah AbdelSalam Mohamed , Wafaa Osman Bahr
Material type:
- حسابات الجرع الاشعاعية المؤينة لانطلاق اليود 131 الناتج من حالات الحوادث لمفاعل اختيار المواد [Added title page title]
- Issued also as CD
Item type | Current library | Home library | Call number | Copy number | Status | Barcode | |
---|---|---|---|---|---|---|---|
![]() |
قاعة الرسائل الجامعية - الدور الاول | المكتبة المركزبة الجديدة - جامعة القاهرة | Cai01.12.20.M.Sc.2021.Ma.I (Browse shelf(Opens below)) | Not for loan | 01010110084756000 | ||
![]() |
مخـــزن الرســائل الجـــامعية - البدروم | المكتبة المركزبة الجديدة - جامعة القاهرة | Cai01.12.20.M.Sc.2021.Ma.I (Browse shelf(Opens below)) | 84756.CD | Not for loan | 01020110084756000 |
Browsing المكتبة المركزبة الجديدة - جامعة القاهرة shelves Close shelf browser (Hides shelf browser)
No cover image available | No cover image available | No cover image available | No cover image available | No cover image available | No cover image available | No cover image available | ||
Cai01.12.20.M.Sc.2021.Ay.M. Molecular structure studies for graphene and functionalized graphene / | Cai01.12.20.M.Sc.2021.Fa.S Standardization of thermal / fast neutron doses for metrological applications / | Cai01.12.20.M.Sc.2021.Fa.S Standardization of thermal / fast neutron doses for metrological applications / | Cai01.12.20.M.Sc.2021.Ma.I Ionising radiation dose calculation for the realse of I¹³¹ during accident conditions for materials test reactor / | Cai01.12.20.M.Sc.2021.Ma.I Ionising radiation dose calculation for the realse of I¹³¹ during accident conditions for materials test reactor / | Cai01.12.20.M.Sc.2021.Ma.I Investigation of different factorsaffecting metal surface emission | Cai01.12.20.M.Sc.2021.Ma.S Search for dark matter associated with higgs boson from heavy Z' decay at the compact muon solenoid / |
Thesis (M.Sc.) - Cairo University - Faculty of Science - Department of Physics
The doses and dose rates following a Loss of Coolant Accident (LOCA) in Material Test Reactor MTR reactor have been studied. MTR reactor is an open water pool reactor type. The water pool serves as a shield from radioactive radiations. The most serious accident in this type of reactor is the Loss of Coolant Accident (LOCA) due to rupture either of a primary coolant pipe or of any experimental beam tube. In the present work it has been assumed that pool water drains out due to double ended rupture of the tangential irradiation beam tube (TIC) which has a diameter 150 mm. For an operating power level of 22 MW, the equilibrium core would enter into melting conditions if the pool drain time is less than one hour. It was also assumed that Emergency Core Cooling System (chimney water injection system and siphon effect breaker) were not working. Therefore conservatively a severe damage (~80%) is expected to occur to the core, either by a core uncover situation following extended boiling operation, or by a core covered situation with extended boiling