Optimization of the performance of grid-connected wind{u2013}driven double-fed induction generator / Ayman Mohamed Abdalsamie Abdalhaliem ; Supervised Adel Shaltout , Hussein Abdelkhalek Attia

By: Contributor(s): Material type: TextTextLanguage: English Publication details: Cairo : Ayman Mohamed Abdalsamie Abdalhaliem , 2018Description: 88 P. : charts , photographs ; 30cmOther title:
  • التشغيل الامثل لمولدات الحث ذات التغذية المزدوجة المدارة بطاقة الرياح والمتصلة بالشبكة [Added title page title]
Subject(s): Available additional physical forms:
  • Issued also as CD
Dissertation note: Thesis (M.Sc.) - Cairo University - Faculty of Engineering - Department of Electrical Power and Machines Summary: A complete study of the effect of injecting the rotor of the double fed induction generator with a voltage that is variable in both magnitude and phase angle which resulted in optimization of the performance of the double fed induction generator to achieve the point of maximum power extracted from wind and one of two options, either obtaining minimum losses or operating at a preset power factor value. A comparison has been conducted between the double fed induction generator performance using the employed control strategies and the single fed induction generator
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Home library Call number Copy number Status Date due Barcode
Thesis Thesis قاعة الرسائل الجامعية - الدور الاول المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.13.07.M.Sc.2018.Ay.O (Browse shelf(Opens below)) Not for loan 01010110076970000
CD - Rom CD - Rom مخـــزن الرســائل الجـــامعية - البدروم المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.13.07.M.Sc.2018.Ay.O (Browse shelf(Opens below)) 76970.CD Not for loan 01020110076970000

Thesis (M.Sc.) - Cairo University - Faculty of Engineering - Department of Electrical Power and Machines

A complete study of the effect of injecting the rotor of the double fed induction generator with a voltage that is variable in both magnitude and phase angle which resulted in optimization of the performance of the double fed induction generator to achieve the point of maximum power extracted from wind and one of two options, either obtaining minimum losses or operating at a preset power factor value. A comparison has been conducted between the double fed induction generator performance using the employed control strategies and the single fed induction generator