Image from OpenLibrary

Comparative study of brachytherapy using ring and ovoid applicators in treatment of advanced cervical cancer / by Hend Mohamed Mahmoud Abd El-Kareem ; Supervisors Prof. Dr. Fadel Mohamed Ali, Prof. Dr. Reem Hassan El-Gebaly, Dr. Reham Salah El-Din Sherif, Prof. Dr. Mohmmad Aboulfetouh Shehata, Dr. Reham Ahmed Abdel Aziz Hassan.

By: Contributor(s): Material type: TextLanguage: English Summary language: English, Arabic Producer: 2025Description: 92 pages : illustrations ; 25 cm. + CDContent type:
  • text
Media type:
  • Unmediated
Carrier type:
  • volume
Other title:
  • دراسة مقارنة للمعالجة الكثبية باستخدام المجسات الحلقية والبيضاوية في سرطان عنق الرحم المتقدم [Added title page title]
Subject(s): DDC classification:
  • 616.99466
Available additional physical forms:
  • Issues also as CD.
Dissertation note: Thesis (Ph.D)-Cairo University, 2025. Summary: Introduction: Image-guided brachytherapy became essential to cervical cancer treatment following chemo-radiotherapy. A variety of applicators and optimization techniques, including Tandem-Ring (TR) and Tandem-Ovoid (TO) applicators, are used to apply brachytherapy. This study aims to dosimetrically compare TR vs. TO applicators and Ring (R) vs. Ovoid (O) applicators by using two different optimization techniques. Materials and Methods: 45 patients were divided into two groups: TR vs. TO group and R vs. O group; both applicator sets were applied to the same patients. The prescribed dose was 7.0 Gy/fraction, and the treatment plans were normalized to HR-CTV. Two different optimization techniques were applied along the four treatment fractions. The first optimization technique was a theoretical assumption that was normalized to HR-CTV and aimed at delivering 7.0 Gy to 90% of the volume of the HR-CTV. While the second aimed to preserve the organs at risk (OARs) according to the ICRU 89 dose-volume constraints, taking into account that 90% of HR- CTV is covered by not less than 90% of the prescribed dose. DVHs were generated, and dosimetric parameters including left and right of points A and B, D2.0cc of rectum, bladder, and sigmoid, as well as the dose at different volumes of HR-CTV and IR-CTV, and total fraction time, were recorded and compared. Results: The results demonstrate that using Ovoid applicators either with or without tandem applicators achieved significantly higher dose at point A, significantly higher coverage to both HR-CTV and IR-CTV, in addition to significantly better protection to the mean D2.0cc of the rectum in both optimization techniques. On the other hand, using ring applicators either with or without tandem applicators give significantly more protection 3 to the mean D2.0cc of the bladder, but HR-CTV and IR-CTV have significantly lower coverage. Conclusion: Tandem-Ovoid a n d Tandem-Ring applicators are the most common interchangeable intracavitary gynecological applicators. In this study, the results demonstrated that both ovoid applicator sets have the advantages of significantly higher coverage for HR-CTV, IR- CTV, and more protection for D2.0cc of the rectum. On the contrary, both ring applicator sets can provide higher protection for D2.0cc of the bladder, and more comfort to the patients. Summary: المقدمة: أصبح العلاج الإشعاعي الموضعي الموجه بالصور ضروريًا لعلاج سرطان عنق الرحم بعد العلاج الكيميائي الإشعاعي. يتم استخدام مجموعة متنوعة من أدوات التطبيق و المجسات وتقنيات التحسين بما في ذلك استخدام المجسات Tandem-Ring (TR) و Tandem-Ovoid (TO) لتطبيق العلاج الإشعاعي الموضعي. تهدف هذه الدراسة إلى مقارنة مجسات TR مقابل TO وأدوات تطبيق Ring (R) مقابل Ovoid (O) باستخدام تقنيتين مختلفتين للتحسين. المواد والطرق: تم تقسيم 45 مريضا إلى مجموعتين. مجموعة TR مقابل TO ومجموعة R مقابل O ، تم تطبيق كلتا المجموعتين على نفس المريض. كانت الجرعة الموصوفة 7 غراي لكل جلسة علاج ، وتم حساب خطط العلاج إلى HR-CTV. يتم تطبيق تقنيتين مختلفتين للتحسين، على طول جلسات المعالجة الأربعة. كانت تقنية التحسين الأولى عبارة عن افتراض نظري يهدف إلى توصيل 7 غراي إلى 90٪ من حجم HR-CTV. بينما يهدف الثاني إلى الحفاظ على الأعضاء المعرضة للخطر (OARs) وفقًا لقيود الجرعة الموصى عليها من قبل ICRU 89، مع الأخذ في الاعتبار أن 90٪ من HR-CTV يتم تغطيتها بما لا يقل عن 90٪ من الجرعة الموصوفة. تم استخراج الرسم البياني للجرعة والحجم ، وتم تسجيل متغيرات قياس الجرعات بما في ذلك يسار ويمين النقطتين A وB، وD2cc للمستقيم والمثانة والسيني، بالإضافة إلى الجرعة المسلمة لأحجام مختلفة من HR-CTV وIR-CTV، وإجمالي وقت جلسات المعالجة . وتم المقارنة بينهم. النتائج: أظهرت النتائج أن استخدام مجسات ال Ovoid سواء مع أو بدون مجسات ال Tandem حقق جرعة أعلى بكثير عند النقطة A، وتغطية أعلى بكثير لكل من HR-CTV وIR-CTV، بالإضافة إلى حماية أفضل بكثير لمتوسط D2cc للمستقيم في كلا تقنيات التحسين. أما من ناحية أخرى، فإن استخدام مجسات ال Ring ال Ovoid سواء مع أو بدون مجسات ال Tandem يوفر حماية أكبر بكثير لمتوسط D2cc للمثانة، لكن HR-CTV وIR-CTV لهما تغطية أقل بكثير.
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Home library Call number Status Barcode
Thesis قاعة الرسائل الجامعية - الدور الاول المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.12.04.Ph.D.2025.He.C (Browse shelf(Opens below)) Not for loan 01010110093607000

Thesis (Ph.D)-Cairo University, 2025.

Bibliography: pages 80-89.

Introduction: Image-guided brachytherapy became essential to
cervical cancer treatment following chemo-radiotherapy. A variety
of applicators and optimization techniques, including Tandem-Ring
(TR) and Tandem-Ovoid (TO) applicators, are used to apply
brachytherapy. This study aims to dosimetrically compare TR vs.
TO applicators and Ring (R) vs. Ovoid (O) applicators by using
two different optimization techniques.
Materials and Methods: 45 patients were divided into two groups: TR
vs. TO group and R vs. O group; both applicator sets were applied to the
same patients. The prescribed dose was 7.0 Gy/fraction, and the treatment
plans were normalized to HR-CTV. Two different optimization techniques
were applied along the four treatment fractions. The first optimization
technique was a theoretical assumption that was normalized to HR-CTV
and aimed at delivering 7.0 Gy to 90% of the volume of the HR-CTV.
While the second aimed to preserve the organs at risk (OARs) according to
the ICRU 89 dose-volume constraints, taking into account that 90% of HR-
CTV is covered by not less than 90% of the prescribed dose. DVHs were
generated, and dosimetric parameters including left and right of points A
and B, D2.0cc of rectum, bladder, and sigmoid, as well as the dose at
different volumes of HR-CTV and IR-CTV, and total fraction time, were
recorded and compared.
Results: The results demonstrate that using Ovoid applicators either with
or without tandem applicators achieved significantly higher dose at point A,
significantly higher coverage to both HR-CTV and IR-CTV, in addition to
significantly better protection to the mean D2.0cc of the rectum in
both optimization techniques. On the other hand, using ring applicators
either with or without tandem applicators give significantly more protection




3





to the mean D2.0cc of the bladder, but HR-CTV and IR-CTV have
significantly lower coverage.
Conclusion: Tandem-Ovoid a n d Tandem-Ring applicators are the
most common interchangeable intracavitary gynecological applicators. In
this study, the results demonstrated that both ovoid applicator sets have
the advantages of significantly higher coverage for HR-CTV, IR-
CTV, and more protection for D2.0cc of the rectum. On the contrary,
both ring applicator sets can provide higher protection for D2.0cc of
the bladder, and more comfort to the patients.

المقدمة: أصبح العلاج الإشعاعي الموضعي الموجه بالصور ضروريًا لعلاج سرطان عنق الرحم بعد العلاج الكيميائي الإشعاعي. يتم استخدام مجموعة متنوعة من أدوات التطبيق و المجسات وتقنيات التحسين بما في ذلك استخدام المجسات Tandem-Ring (TR) و Tandem-Ovoid (TO) لتطبيق العلاج الإشعاعي الموضعي. تهدف هذه الدراسة إلى مقارنة مجسات TR مقابل TO وأدوات تطبيق Ring (R) مقابل Ovoid (O) باستخدام تقنيتين مختلفتين للتحسين.
المواد والطرق: تم تقسيم 45 مريضا إلى مجموعتين. مجموعة TR مقابل TO ومجموعة R مقابل O ، تم تطبيق كلتا المجموعتين على نفس المريض. كانت الجرعة الموصوفة 7 غراي لكل جلسة علاج ، وتم حساب خطط العلاج إلى HR-CTV. يتم تطبيق تقنيتين مختلفتين للتحسين، على طول جلسات المعالجة الأربعة. كانت تقنية التحسين الأولى عبارة عن افتراض نظري يهدف إلى توصيل 7 غراي إلى 90٪ من حجم HR-CTV.
بينما يهدف الثاني إلى الحفاظ على الأعضاء المعرضة للخطر (OARs) وفقًا لقيود الجرعة الموصى عليها من قبل ICRU 89، مع الأخذ في الاعتبار أن 90٪ من HR-CTV يتم تغطيتها بما لا يقل عن 90٪ من الجرعة الموصوفة.
تم استخراج الرسم البياني للجرعة والحجم ، وتم تسجيل متغيرات قياس الجرعات بما في ذلك يسار ويمين النقطتين A وB، وD2cc للمستقيم والمثانة والسيني، بالإضافة إلى الجرعة المسلمة لأحجام مختلفة من HR-CTV وIR-CTV، وإجمالي وقت جلسات المعالجة . وتم المقارنة بينهم.
النتائج: أظهرت النتائج أن استخدام مجسات ال Ovoid سواء مع أو بدون مجسات ال Tandem حقق جرعة أعلى بكثير عند النقطة A، وتغطية أعلى بكثير لكل من HR-CTV وIR-CTV، بالإضافة إلى حماية أفضل بكثير لمتوسط D2cc للمستقيم في كلا تقنيات التحسين.
أما من ناحية أخرى، فإن استخدام مجسات ال Ring ال Ovoid سواء مع أو بدون مجسات ال Tandem يوفر حماية أكبر بكثير لمتوسط D2cc للمثانة، لكن HR-CTV وIR-CTV لهما تغطية أقل بكثير.

Issues also as CD.

Text in English and abstract in Arabic & English.

There are no comments on this title.

to post a comment.
Share
Cairo University Libraries Portal Implemented & Customized by: Eng. M. Mohamady Contacts: new-lib@cl.cu.edu.eg | cnul@cl.cu.edu.eg
CUCL logo CNUL logo
© All rights reserved — Cairo University Libraries
CUCL logo
Implemented & Customized by: Eng. M. Mohamady Contact: new-lib@cl.cu.edu.eg © All rights reserved — New Central Library
CNUL logo
Implemented & Customized by: Eng. M. Mohamady Contact: cnul@cl.cu.edu.eg © All rights reserved — Cairo National University Library