Efficacy of different co2 laser outputs versus sandblasting surface treatment on bonding of zirconia to adhesive resin : An in vitro study/
Haitham Ali Ezzat Emam,
Efficacy of different co2 laser outputs versus sandblasting surface treatment on bonding of zirconia to adhesive resin : An in vitro study/ تأثير المعالجة باستخدام ليزر ثاني أكسيد الكربون مقابل المعالجة السطحية بالسفع الرملي على ربط الزركونيا بالمادة اللاصقة : دراسة معملية / By Haitham Ali Ezzat Emam ; Supervisors Prof. Dr. Omaima Salah El Dein El Mahallawi, Dr. Abdel Rahman Soliman Badran, Dr. Gomaa Abdullah Hussein Soliman . - 102 pages : illustrations ; 25 cm. + CD.
Thesis (M.Sc.) Cairo University, 2023.
Bibliography: pages 95-101.
The aim of the present study was to evaluate the effect of different CO laser output as a laser
surface treatment on the shear bond strength of zirconia to resin cement.
A total number of 21 square shape zirconia specimens with the dimensions of 10x10x2 mm
after sintering cycle were sliced out of IPS e.max ZirCAD Prime disc via Isomet 4000, were subjected
to different methods of surface-treatments and classified equally into 3 Groups; Sandblasting 50µm
Al2O3 Group, CO 3 watt Laser Group, CO 4 watt Laser Group, all specimens of different groups
2 2
were subjected to surface roughness analysis via Digital-Microscope , and additional specimens for
each group were used for Scanning-Electron-Microscope imaging.
All specimens were cemented to dual cure self-adhesive resin cement via customized teflon
mold to obtain a circular cement layer of 2 mm height and 4 mm diameters, then all bonded specimens
will be subjected to shear bond strength test by using universal testing machine, that performed with
a cross-head speed of 0.5 mm/min .
The results of the current study revealed that there was statically significant difference between
Sandblasting group and both CO laser groups, with no statical difference of both CO laser Groups,
2 2
regarding shear bond strength, and All three groups showed no statistical difference regarding surface
roughness average. الهدف من هذه الدراسةة هو تقييم تأثير نواتج ليزر ثاني أكسةةيد الكربون المختلف على ربط الزركونيا بالمادة الالصةةق مقابل
المعالج السطحي بالسفع الرملي.
تم تقطيع ٢١ عينه من الزركونيا ذات الشكل المربع بأبعاد ١٠ × ١٠ × ٢ ملي متر بعد دورة التلبيد بواسط جهاز ايزو
ميت 4000 وعرضهم لمعالج سطح مختلف وهما السفع الرملي و اليزر ثاني اكسيد الكربون ب نواتج مختلفه وهم 3 وات 4 وات ،
خضعت جميع عينات المجموعات المختلف لتحليل خشون السطح عبر مجهر رقمي ، واستخدمت عينات إضافي لكل مجمو
ع
للتصوير الضوئي-اإللكتروني و تم قياس قوة الرابط القصي للعينات باستخدام ال اختبار متعددة االغراض بعد ان تم لصق عينات
الزركونيا بي االسمنت الراتنج بطول 2 ملي متر وقطر 4 ملي متر و تم كسر العينات عبر سرع الرأس بمقدار 0.5 ملي متر /
دقيقه
اظهرت نتاىج الدراسه الحاليه ان هناك فرق ذو دالله إحصائيه بين مجموع الزركونيا المعالج با لسفع الرملي و كال
مجموعتي الليزر فيما يتعلق بقوة اللصق ، و ان ال يوجد فرق ذو دالله إحصائيه بين مجموع الزركونيا المعالج با لسفع الرملي و
كال مجموعتي الليزر فيما يتعلق بخشون السطح .
النتائج:
1. ال يمكن استخدام ليزر ثاني أكسيد الكربون كطريق بديل للسفع الرملي في المعالجه السطحيه للزركونيا، ألنه لم يعزز قوة
ارتباط الزركونيا باإلسمنت الراتينج..
2. أظهرت المعالجات السطحي المختلف بعد التلبيد تغييرات مورفولوجي وطبوغرافي على سطح الزركونيا.
Text in English and abstract in English.
Fixed Prosthodontics
co2 laser sandblasting surface treatment zirconia
617.695
Efficacy of different co2 laser outputs versus sandblasting surface treatment on bonding of zirconia to adhesive resin : An in vitro study/ تأثير المعالجة باستخدام ليزر ثاني أكسيد الكربون مقابل المعالجة السطحية بالسفع الرملي على ربط الزركونيا بالمادة اللاصقة : دراسة معملية / By Haitham Ali Ezzat Emam ; Supervisors Prof. Dr. Omaima Salah El Dein El Mahallawi, Dr. Abdel Rahman Soliman Badran, Dr. Gomaa Abdullah Hussein Soliman . - 102 pages : illustrations ; 25 cm. + CD.
Thesis (M.Sc.) Cairo University, 2023.
Bibliography: pages 95-101.
The aim of the present study was to evaluate the effect of different CO laser output as a laser
surface treatment on the shear bond strength of zirconia to resin cement.
A total number of 21 square shape zirconia specimens with the dimensions of 10x10x2 mm
after sintering cycle were sliced out of IPS e.max ZirCAD Prime disc via Isomet 4000, were subjected
to different methods of surface-treatments and classified equally into 3 Groups; Sandblasting 50µm
Al2O3 Group, CO 3 watt Laser Group, CO 4 watt Laser Group, all specimens of different groups
2 2
were subjected to surface roughness analysis via Digital-Microscope , and additional specimens for
each group were used for Scanning-Electron-Microscope imaging.
All specimens were cemented to dual cure self-adhesive resin cement via customized teflon
mold to obtain a circular cement layer of 2 mm height and 4 mm diameters, then all bonded specimens
will be subjected to shear bond strength test by using universal testing machine, that performed with
a cross-head speed of 0.5 mm/min .
The results of the current study revealed that there was statically significant difference between
Sandblasting group and both CO laser groups, with no statical difference of both CO laser Groups,
2 2
regarding shear bond strength, and All three groups showed no statistical difference regarding surface
roughness average. الهدف من هذه الدراسةة هو تقييم تأثير نواتج ليزر ثاني أكسةةيد الكربون المختلف على ربط الزركونيا بالمادة الالصةةق مقابل
المعالج السطحي بالسفع الرملي.
تم تقطيع ٢١ عينه من الزركونيا ذات الشكل المربع بأبعاد ١٠ × ١٠ × ٢ ملي متر بعد دورة التلبيد بواسط جهاز ايزو
ميت 4000 وعرضهم لمعالج سطح مختلف وهما السفع الرملي و اليزر ثاني اكسيد الكربون ب نواتج مختلفه وهم 3 وات 4 وات ،
خضعت جميع عينات المجموعات المختلف لتحليل خشون السطح عبر مجهر رقمي ، واستخدمت عينات إضافي لكل مجمو
ع
للتصوير الضوئي-اإللكتروني و تم قياس قوة الرابط القصي للعينات باستخدام ال اختبار متعددة االغراض بعد ان تم لصق عينات
الزركونيا بي االسمنت الراتنج بطول 2 ملي متر وقطر 4 ملي متر و تم كسر العينات عبر سرع الرأس بمقدار 0.5 ملي متر /
دقيقه
اظهرت نتاىج الدراسه الحاليه ان هناك فرق ذو دالله إحصائيه بين مجموع الزركونيا المعالج با لسفع الرملي و كال
مجموعتي الليزر فيما يتعلق بقوة اللصق ، و ان ال يوجد فرق ذو دالله إحصائيه بين مجموع الزركونيا المعالج با لسفع الرملي و
كال مجموعتي الليزر فيما يتعلق بخشون السطح .
النتائج:
1. ال يمكن استخدام ليزر ثاني أكسيد الكربون كطريق بديل للسفع الرملي في المعالجه السطحيه للزركونيا، ألنه لم يعزز قوة
ارتباط الزركونيا باإلسمنت الراتينج..
2. أظهرت المعالجات السطحي المختلف بعد التلبيد تغييرات مورفولوجي وطبوغرافي على سطح الزركونيا.
Text in English and abstract in English.
Fixed Prosthodontics
co2 laser sandblasting surface treatment zirconia
617.695