Four digital intraoral scanners versus conventional impression technique : (Record no. 172648)
[ view plain ]
000 -LEADER | |
---|---|
fixed length control field | 07080namaa22004211i 4500 |
003 - CONTROL NUMBER IDENTIFIER | |
control field | OSt |
005 - أخر تعامل مع التسجيلة | |
control field | 20250618154910.0 |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
fixed length control field | 250618s2024 a|||frm||| 000 0 eng d |
040 ## - CATALOGING SOURCE | |
Original cataloguing agency | EG-GICUC |
Language of cataloging | eng |
Transcribing agency | EG-GICUC |
Modifying agency | EG-GICUC |
Description conventions | rda |
041 0# - LANGUAGE CODE | |
Language code of text/sound track or separate title | eng |
Language code of summary or abstract | eng |
-- | ara |
049 ## - Acquisition Source | |
Acquisition Source | Deposit |
082 04 - DEWEY DECIMAL CLASSIFICATION NUMBER | |
Classification number | 617.69 |
092 ## - LOCALLY ASSIGNED DEWEY CALL NUMBER (OCLC) | |
Classification number | 617.69 |
Edition number | 21 |
097 ## - Degree | |
Degree | M.Sc |
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC) | |
Local Call Number | Cai01.09.13.M.Sc.2024.Re.F |
100 0# - MAIN ENTRY--PERSONAL NAME | |
Authority record control number or standard number | Reham Ragab, |
Preparation | preparation. |
245 10 - TITLE STATEMENT | |
Title | Four digital intraoral scanners versus conventional impression technique : |
Remainder of title | an invitro evaluation of fit accuracy on multiunit abutments for cross arch implant restorations / |
Statement of responsibility, etc. | by Reham Ragab ; Supervision Dr: Atef Shaker, Dr: Mohamed El Khashab. |
246 15 - VARYING FORM OF TITLE | |
Title proper/short title | أربعة ماسحات رقمية داخل الفم مقابل الطريقة التقليدية : |
Remainder of title | : دراسة معملية لتقييم دقة التناسب على الدعم متعدد الوحدات لترميم زراعة قوس الفم دراسه معمليه / |
264 #0 - PRODUCTION, PUBLICATION, DISTRIBUTION, MANUFACTURE, AND COPYRIGHT NOTICE | |
Date of production, publication, distribution, manufacture, or copyright notice | 2024. |
300 ## - PHYSICAL DESCRIPTION | |
Extent | 109 pages : |
Other physical details | illustrations ; |
Dimensions | 25 cm. + |
Accompanying material | CD. |
336 ## - CONTENT TYPE | |
Content type term | text |
Source | rda content |
337 ## - MEDIA TYPE | |
Media type term | Unmediated |
Source | rdamedia |
338 ## - CARRIER TYPE | |
Carrier type term | volume |
Source | rdacarrier |
502 ## - DISSERTATION NOTE | |
Dissertation note | Thesis (M.Sc)-Cairo University, 2024. |
504 ## - BIBLIOGRAPHY, ETC. NOTE | |
Bibliography, etc. note | Bibliography: pages 88-105. |
520 ## - SUMMARY, ETC. | |
Summary, etc. | Aim: The aim of this study to compare the passive fit of full arch implant zirconium superstructure <br/>using conventional impression versus digital impression with 4 intraoral scanners (CEREC <br/>primscan, CRERC omnicam, medit i700 and 3shape trios4). <br/>Methodology: four implants installed in the epoxy mandibular cast. All implants installed using <br/>dental surveyor to ensure parallelism of all 4 implants, installed in premolar-molar areas bilaterally. <br/>25 frameworks are fabricated; in group 1 twenty milled frameworks fabricated using a digital <br/>intraoral scanners (primescan ,omnicam ,medit i700 and 3shape trios4), while in group 2 five <br/>conventional frameworks using a conventional open tray impression. <br/>In Group 1 Scan bodies will be screwed to the installed implants, and five digital impressions using <br/>an intra-oral scanner will be carried out for each scanner. The STL files of the twenty impressions <br/>will be used to fabricate twenty milled frameworks using exocad software. <br/>Group 2 Five Splinted open tray conventional Impressions carried out, then the impression was <br/>poured in a conventional manner to obtain a stone master cast. This master cast used for fabrication <br/>of a milled zirconia superstructure frameworks after scanning the cast with desktop scanner (Medit <br/>T300). <br/>Passive fit of all frameworks fabricated in the two groups were evaluated using the shiefield test <br/>(one screw test) and that is assessed as passive or non-passive, and gap distance will be measured <br/>using stereomicroscope when all implants screws are tightened (active fit). <br/>Results: All frameworks were considered passive using the one screw test. Primscan showed the <br/>lowest marginal gap values. 3shape trios4 , omnicam and medit i700 showed similar gap values . <br/>while the highest gap values were presented in conventional impression group. <br/><br/><br/>vii <br/><br/>Conclusions: intraoral scanners can be used efficiently in cross-arch implant restoration impression <br/>using scan bodies. primscan proved to be higher in precision than other tested intraoral scanners. <br/>And finally digital implant supported restorations workflow can replace conventional implant <br/>supported workflow in the daily practice. |
520 ## - SUMMARY, ETC. | |
Summary, etc. | الهدف من إجراء البحث :<br/>لتقييم الملائمة والدقة للهياكل الفوقية للزيركونيا " الكل على أربعة" المصممة والمصنعة رقميا مقارنة بتقنية الانطباع التقليدية.<br/>الاجراءات العلميه : <br/>في هذا البحث, تم استخدام نموذج مصبوب من الريزن الجاهز من الفك السفلي ، وتركيب أربعة غرسات في منطقة مابين ثقب الفك السفلي.<br/>في هذه الدراسة تم تصنيع خمسه وعشرون إطر.<br/>في المجموعة 1: تم ربط أجسام المسح بجميع الغرسات المثبتة ، وتم إجراء عشرين طبعة رقمية باستخدام الماسح الضوئي داخل الفم نوع مديت ، برايم سكان ، سيريك امنيكام و 3 شيب تريوس . تم استخدام ملفات STL للطبعات العشرون لتصنيع 10 إطار عمل للبنية الفوقية باستخدام برنامج الاكسوكاد.<br/>المجموعة 2: تم تنفيذ الانطباعات التقليدية الخمس ذات الدرج المفتوح لجميع الغرسات الاربعة المثبتة ، وتم سكب كل انطباع بطريقه تقليدية للحصول على قالب رئيسي.<br/>تم تقييم التوافق السلبي لجميع الأطر المصنعة في المجموعتين في الدراسة المعملية الحالية باستخدام طريقيتين ؛ الطريقة الأولى هي اختبار شيفيلد والذي سيتم تقييمه على انه سلبي أو غير سلبي ، والطريقة الثانية كانت قياس مسافة الفجوة باستخدام الميكرسكوب المجسم عندما تكون جميع المسامير مربوطة بالكامل.<br/>مقاييس النتائج:<br/> جميع الاطر اظهرت 100% دقه في كلا المجموعتين .أظهرت الأطر الرقمية المطحونة فرقا كبيرا أقل مقارنة بالأطر التقليدية. أظهر سيريك برايمسكان أدنى فرق معنوي بين جميع المجموعات المختبرة بينما أظهر الانطباع التقليدي الأعلى. <br/><br/><br/><br/>الخلاصه :<br/>من نتائج الدراسة الحالية يمكننا ان نلخص ما يلي:<br/>1-يمكن استخدام الماسحات الضوئية داخل الفم بكفاءة في انطباعات ترميم الغرسات المتقاطعة باستخدام أجسام المسح.<br/>2-أثبت برايم سكان أنه أعلى في الدقة من الماسحات الضوئية داخل الفم المختبرة الاخرى.<br/>3-يمكن ان يحل سير عمل الترميمات المدعومة بالغرسة الرقمية محل سير العمل المدعوم بالزرع التقليدي في الممارسة اليومية. |
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE | |
Issues CD | Issues also as CD. |
546 ## - LANGUAGE NOTE | |
Text Language | Text in English and abstract in Arabic & English. |
650 #7 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
Topical term or geographic name entry element | Oral Implantology |
Source of heading or term | qrmak |
653 #0 - INDEX TERM--UNCONTROLLED | |
Uncontrolled term | Dental implant |
-- | CAD/CAM |
-- | scan bodies |
-- | marginal accuracy |
-- | digital intra-oral scanners |
700 0# - ADDED ENTRY--PERSONAL NAME | |
Personal name | Atef Shaker |
Relator term | thesis advisor. |
700 0# - ADDED ENTRY--PERSONAL NAME | |
Personal name | Mohamed El Khashab |
Relator term | thesis advisor. |
900 ## - Thesis Information | |
Grant date | 01-01-2024 |
Supervisory body | Atef Shaker |
-- | Mohamed El Khashab |
Universities | Cairo University |
Faculties | Faculty of Dentistry |
Department | Department of Oral Implantology |
905 ## - Cataloger and Reviser Names | |
Cataloger Name | Shimaa |
942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
Source of classification or shelving scheme | Dewey Decimal Classification |
Koha item type | Thesis |
Edition | 21 |
Suppress in OPAC | No |
Source of classification or shelving scheme | Home library | Current library | Date acquired | Inventory number | Full call number | Barcode | Date last seen | Effective from | Koha item type |
---|---|---|---|---|---|---|---|---|---|
Dewey Decimal Classification | المكتبة المركزبة الجديدة - جامعة القاهرة | قاعة الرسائل الجامعية - الدور الاول | 18.06.2025 | 91431 | Cai01.09.13.M.Sc.2024.Re.F | 01010110091431000 | 18.06.2025 | 18.06.2025 | Thesis |