Four digital intraoral scanners versus conventional impression technique : an invitro evaluation of fit accuracy on multiunit abutments for cross arch implant restorations / by Reham Ragab ; Supervision Dr: Atef Shaker, Dr: Mohamed El Khashab.

By: Contributor(s): Material type: TextTextLanguage: English Summary language: English, Arabic Producer: 2024Description: 109 pages : illustrations ; 25 cm. + CDContent type:
  • text
Media type:
  • Unmediated
Carrier type:
  • volume
Other title:
  • أربعة ماسحات رقمية داخل الفم مقابل الطريقة التقليدية : : دراسة معملية لتقييم دقة التناسب على الدعم متعدد الوحدات لترميم زراعة قوس الفم دراسه معمليه [Added title page title]
Subject(s): DDC classification:
  • 617.69
Available additional physical forms:
  • Issues also as CD.
Dissertation note: Thesis (M.Sc)-Cairo University, 2024. Summary: Aim: The aim of this study to compare the passive fit of full arch implant zirconium superstructure using conventional impression versus digital impression with 4 intraoral scanners (CEREC primscan, CRERC omnicam, medit i700 and 3shape trios4). Methodology: four implants installed in the epoxy mandibular cast. All implants installed using dental surveyor to ensure parallelism of all 4 implants, installed in premolar-molar areas bilaterally. 25 frameworks are fabricated; in group 1 twenty milled frameworks fabricated using a digital intraoral scanners (primescan ,omnicam ,medit i700 and 3shape trios4), while in group 2 five conventional frameworks using a conventional open tray impression. In Group 1 Scan bodies will be screwed to the installed implants, and five digital impressions using an intra-oral scanner will be carried out for each scanner. The STL files of the twenty impressions will be used to fabricate twenty milled frameworks using exocad software. Group 2 Five Splinted open tray conventional Impressions carried out, then the impression was poured in a conventional manner to obtain a stone master cast. This master cast used for fabrication of a milled zirconia superstructure frameworks after scanning the cast with desktop scanner (Medit T300). Passive fit of all frameworks fabricated in the two groups were evaluated using the shiefield test (one screw test) and that is assessed as passive or non-passive, and gap distance will be measured using stereomicroscope when all implants screws are tightened (active fit). Results: All frameworks were considered passive using the one screw test. Primscan showed the lowest marginal gap values. 3shape trios4 , omnicam and medit i700 showed similar gap values . while the highest gap values were presented in conventional impression group. vii Conclusions: intraoral scanners can be used efficiently in cross-arch implant restoration impression using scan bodies. primscan proved to be higher in precision than other tested intraoral scanners. And finally digital implant supported restorations workflow can replace conventional implant supported workflow in the daily practice. Summary: الهدف من إجراء البحث : لتقييم الملائمة والدقة للهياكل الفوقية للزيركونيا " الكل على أربعة" المصممة والمصنعة رقميا مقارنة بتقنية الانطباع التقليدية. الاجراءات العلميه : في هذا البحث, تم استخدام نموذج مصبوب من الريزن الجاهز من الفك السفلي ، وتركيب أربعة غرسات في منطقة مابين ثقب الفك السفلي. في هذه الدراسة تم تصنيع خمسه وعشرون إطر. في المجموعة 1: تم ربط أجسام المسح بجميع الغرسات المثبتة ، وتم إجراء عشرين طبعة رقمية باستخدام الماسح الضوئي داخل الفم نوع مديت ، برايم سكان ، سيريك امنيكام و 3 شيب تريوس . تم استخدام ملفات STL للطبعات العشرون لتصنيع 10 إطار عمل للبنية الفوقية باستخدام برنامج الاكسوكاد. المجموعة 2: تم تنفيذ الانطباعات التقليدية الخمس ذات الدرج المفتوح لجميع الغرسات الاربعة المثبتة ، وتم سكب كل انطباع بطريقه تقليدية للحصول على قالب رئيسي. تم تقييم التوافق السلبي لجميع الأطر المصنعة في المجموعتين في الدراسة المعملية الحالية باستخدام طريقيتين ؛ الطريقة الأولى هي اختبار شيفيلد والذي سيتم تقييمه على انه سلبي أو غير سلبي ، والطريقة الثانية كانت قياس مسافة الفجوة باستخدام الميكرسكوب المجسم عندما تكون جميع المسامير مربوطة بالكامل. مقاييس النتائج: جميع الاطر اظهرت 100% دقه في كلا المجموعتين .أظهرت الأطر الرقمية المطحونة فرقا كبيرا أقل مقارنة بالأطر التقليدية. أظهر سيريك برايمسكان أدنى فرق معنوي بين جميع المجموعات المختبرة بينما أظهر الانطباع التقليدي الأعلى. الخلاصه : من نتائج الدراسة الحالية يمكننا ان نلخص ما يلي: 1-يمكن استخدام الماسحات الضوئية داخل الفم بكفاءة في انطباعات ترميم الغرسات المتقاطعة باستخدام أجسام المسح. 2-أثبت برايم سكان أنه أعلى في الدقة من الماسحات الضوئية داخل الفم المختبرة الاخرى. 3-يمكن ان يحل سير عمل الترميمات المدعومة بالغرسة الرقمية محل سير العمل المدعوم بالزرع التقليدي في الممارسة اليومية.
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Home library Call number Status Barcode
Thesis Thesis قاعة الرسائل الجامعية - الدور الاول المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.09.13.M.Sc.2024.Re.F (Browse shelf(Opens below)) Not for loan 01010110091431000

Thesis (M.Sc)-Cairo University, 2024.

Bibliography: pages 88-105.

Aim: The aim of this study to compare the passive fit of full arch implant zirconium superstructure
using conventional impression versus digital impression with 4 intraoral scanners (CEREC
primscan, CRERC omnicam, medit i700 and 3shape trios4).
Methodology: four implants installed in the epoxy mandibular cast. All implants installed using
dental surveyor to ensure parallelism of all 4 implants, installed in premolar-molar areas bilaterally.
25 frameworks are fabricated; in group 1 twenty milled frameworks fabricated using a digital
intraoral scanners (primescan ,omnicam ,medit i700 and 3shape trios4), while in group 2 five
conventional frameworks using a conventional open tray impression.
In Group 1 Scan bodies will be screwed to the installed implants, and five digital impressions using
an intra-oral scanner will be carried out for each scanner. The STL files of the twenty impressions
will be used to fabricate twenty milled frameworks using exocad software.
Group 2 Five Splinted open tray conventional Impressions carried out, then the impression was
poured in a conventional manner to obtain a stone master cast. This master cast used for fabrication
of a milled zirconia superstructure frameworks after scanning the cast with desktop scanner (Medit
T300).
Passive fit of all frameworks fabricated in the two groups were evaluated using the shiefield test
(one screw test) and that is assessed as passive or non-passive, and gap distance will be measured
using stereomicroscope when all implants screws are tightened (active fit).
Results: All frameworks were considered passive using the one screw test. Primscan showed the
lowest marginal gap values. 3shape trios4 , omnicam and medit i700 showed similar gap values .
while the highest gap values were presented in conventional impression group.


vii

Conclusions: intraoral scanners can be used efficiently in cross-arch implant restoration impression
using scan bodies. primscan proved to be higher in precision than other tested intraoral scanners.
And finally digital implant supported restorations workflow can replace conventional implant
supported workflow in the daily practice.

الهدف من إجراء البحث :
لتقييم الملائمة والدقة للهياكل الفوقية للزيركونيا " الكل على أربعة" المصممة والمصنعة رقميا مقارنة بتقنية الانطباع التقليدية.
الاجراءات العلميه :
في هذا البحث, تم استخدام نموذج مصبوب من الريزن الجاهز من الفك السفلي ، وتركيب أربعة غرسات في منطقة مابين ثقب الفك السفلي.
في هذه الدراسة تم تصنيع خمسه وعشرون إطر.
في المجموعة 1: تم ربط أجسام المسح بجميع الغرسات المثبتة ، وتم إجراء عشرين طبعة رقمية باستخدام الماسح الضوئي داخل الفم نوع مديت ، برايم سكان ، سيريك امنيكام و 3 شيب تريوس . تم استخدام ملفات STL للطبعات العشرون لتصنيع 10 إطار عمل للبنية الفوقية باستخدام برنامج الاكسوكاد.
المجموعة 2: تم تنفيذ الانطباعات التقليدية الخمس ذات الدرج المفتوح لجميع الغرسات الاربعة المثبتة ، وتم سكب كل انطباع بطريقه تقليدية للحصول على قالب رئيسي.
تم تقييم التوافق السلبي لجميع الأطر المصنعة في المجموعتين في الدراسة المعملية الحالية باستخدام طريقيتين ؛ الطريقة الأولى هي اختبار شيفيلد والذي سيتم تقييمه على انه سلبي أو غير سلبي ، والطريقة الثانية كانت قياس مسافة الفجوة باستخدام الميكرسكوب المجسم عندما تكون جميع المسامير مربوطة بالكامل.
مقاييس النتائج:
جميع الاطر اظهرت 100% دقه في كلا المجموعتين .أظهرت الأطر الرقمية المطحونة فرقا كبيرا أقل مقارنة بالأطر التقليدية. أظهر سيريك برايمسكان أدنى فرق معنوي بين جميع المجموعات المختبرة بينما أظهر الانطباع التقليدي الأعلى.



الخلاصه :
من نتائج الدراسة الحالية يمكننا ان نلخص ما يلي:
1-يمكن استخدام الماسحات الضوئية داخل الفم بكفاءة في انطباعات ترميم الغرسات المتقاطعة باستخدام أجسام المسح.
2-أثبت برايم سكان أنه أعلى في الدقة من الماسحات الضوئية داخل الفم المختبرة الاخرى.
3-يمكن ان يحل سير عمل الترميمات المدعومة بالغرسة الرقمية محل سير العمل المدعوم بالزرع التقليدي في الممارسة اليومية.

Issues also as CD.

Text in English and abstract in Arabic & English.

There are no comments on this title.

to post a comment.
Share
Under the supervision of New Central Library Manager

Implemented and Customized by: Eng.M.Mohamady
Contact:   info@cl.cu.edu.eg

© All rights reserved  New Central Library