Wireless control of magnetic drug carriers using a magnetic-based robotic system / (Record no. 62034)

MARC details
000 -LEADER
fixed length control field 01770cam a2200313 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250223031757.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 170819s2015 ua ho f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Gift
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.34.M.Sc.2015.Bi.W
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Bishoy Emil Edward Wissa
245 10 - TITLE STATEMENT
Title Wireless control of magnetic drug carriers using a magnetic-based robotic system /
Statement of responsibility, etc. Bishoy Emil Edward Wissa ; Supervised Islam S. M. Khalil , E. I. Imam Morgan
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Bishoy Emil Edward Wissa ,
Date of publication, distribution, etc. 2015
300 ## - PHYSICAL DESCRIPTION
Extent 80 Leaves :
Other physical details facsimiles , photographs ;
Dimensions 30cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - German University - Faculty of Postgraduate Studies and Scientific Research - Department of Mechatronics Engineering
520 ## - SUMMARY, ETC.
Summary, etc. The side-effects of many drugs can be mitigated by using targeted drug delivery. The drug is localized within the vicinity of the smal locatiob of the disease inside the human body. In this thesis, motion control of a paramagnetic microparticle is achieved using a magnetic-based robotic system with an open-configuration. This control is done using a permanent magnet and an electromagnetic coil under microscopic guidance and using visual feedback. The permanent magnet and the electromagnetic coil are fixed to the end-effector of a robotic arm with 4 degrees-of-freedom to control the position of the microparticle
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Magnetic drug
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Magnetic-based robotic system
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Wireless control
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name E. I. Imam Morgan ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Islam S. M. Khalil ,
Relator term
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a>
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Samia
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الثقاقات الاجنبية - الدور الثالث 11.02.2024 Cai01.34.M.Sc.2015.Bi.W 01010110072248000 05.07.2024 Thesis
Cairo University Libraries Portal Implemented & Customized by: Eng. M. Mohamady Contacts: new-lib@cl.cu.edu.eg | cnul@cl.cu.edu.eg
CUCL logo CNUL logo
© All rights reserved — Cairo University Libraries
CUCL logo
Implemented & Customized by: Eng. M. Mohamady Contact: new-lib@cl.cu.edu.eg © All rights reserved — New Central Library
CNUL logo
Implemented & Customized by: Eng. M. Mohamady Contact: cnul@cl.cu.edu.eg © All rights reserved — Cairo National University Library