صورة الغلاف المحلية
صورة الغلاف المحلية
صور من OpenLibrary

Wireless control of magnetic drug carriers using a magnetic-based robotic system / Bishoy Emil Edward Wissa ; Supervised Islam S. M. Khalil , E. I. Imam Morgan

بواسطة: المساهم: نوع المادة : نصاللغة: الإنجليزية تفاصيل النشر: Cairo : Bishoy Emil Edward Wissa , 2015الوصف: 80 Leaves : facsimiles , photographs ; 30cmالموضوع: موارد على الإنترنت: ملاحظة الأطروحة: Thesis (M.Sc.) - German University - Faculty of Postgraduate Studies and Scientific Research - Department of Mechatronics Engineering ملخص: The side-effects of many drugs can be mitigated by using targeted drug delivery. The drug is localized within the vicinity of the smal locatiob of the disease inside the human body. In this thesis, motion control of a paramagnetic microparticle is achieved using a magnetic-based robotic system with an open-configuration. This control is done using a permanent magnet and an electromagnetic coil under microscopic guidance and using visual feedback. The permanent magnet and the electromagnetic coil are fixed to the end-effector of a robotic arm with 4 degrees-of-freedom to control the position of the microparticle
وسوم من هذه المكتبة: لا توجد وسوم لهذا العنوان في هذه المكتبة. قم بتسجيل الدخول لإضافة الوسوم.
التقييم باستخدام النجوم
    متوسط التقييم: 0.0 (0 صوتًا)
المقتنيات
نوع المادة المكتبة الحالية المكتبة الرئيسية رقم الاستدعاء حالة الباركود
Thesis قاعة الثقاقات الاجنبية - الدور الثالث المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.34.M.Sc.2015.Bi.W (استعراض الرف(يفتح أدناه)) لا تعار 01010110072248000

Thesis (M.Sc.) - German University - Faculty of Postgraduate Studies and Scientific Research - Department of Mechatronics Engineering

The side-effects of many drugs can be mitigated by using targeted drug delivery. The drug is localized within the vicinity of the smal locatiob of the disease inside the human body. In this thesis, motion control of a paramagnetic microparticle is achieved using a magnetic-based robotic system with an open-configuration. This control is done using a permanent magnet and an electromagnetic coil under microscopic guidance and using visual feedback. The permanent magnet and the electromagnetic coil are fixed to the end-effector of a robotic arm with 4 degrees-of-freedom to control the position of the microparticle

لا توجد تعليقات على هذا العنوان.

اضغط على الصورة لمشاهدتها في عارض الصور

صورة الغلاف المحلية
شارك
Cairo University Libraries Portal Implemented & Customized by: Eng. M. Mohamady Contacts: new-lib@cl.cu.edu.eg | cnul@cl.cu.edu.eg
CUCL logo CNUL logo
© All rights reserved — Cairo University Libraries
CUCL logo
Implemented & Customized by: Eng. M. Mohamady Contact: new-lib@cl.cu.edu.eg © All rights reserved — New Central Library
CNUL logo
Implemented & Customized by: Eng. M. Mohamady Contact: cnul@cl.cu.edu.eg © All rights reserved — Cairo National University Library