header
Image from OpenLibrary

Evaluation of reliability of impedance spectroscopy (cariescan pro™) in comparison with digital radiograph and icdas-ii in detection of occlusal carious lesions : diagnostic accuracy study / by Amr Ramadan Abd Elkader ; Supervisors Olfat Elsayed Hassanein, Shereen Hafez Ibrahim.

By: Contributor(s): Material type: TextTextLanguage: English Summary language: English, Arabic Producer: 2024Description: 113 pages : illustrations ; 25 cm. + CDContent type:
  • text
Media type:
  • Unmediated
Carrier type:
  • volume
Other title:
  • تقييم الموثوقية لنظام المعاوقة الطيفية الكهربية مقارنة بنتائج الأشعة الرقمية والنظام العالمي الثاني لتحديد التسوس في الكشف عن إصابات التسوس السطحي : دراسة الدقة التشخيصية [Added title page title]
Subject(s): DDC classification:
  • 617.6
Available additional physical forms:
  • Issues also as CD.
Dissertation note: Thesis (Ph.D)-Cairo University, 2024. Summary: Aim: The aim of this study is to evaluate the Clinical performance of (CarieScanPRO™) in comparison with digital radiograph and ICDAS-II in detection of occlusal carious lesions Methodology: Occlusal surfaces of 166 posterior teeth were assessed using three diagnostic procedures. 1) (ICDAS-II), 2) digital radiograph, and 3) CarieScanPRO™ device (ACIST). The diagnostic accuracy and 95% CI for caries detection with CarieScanPRO™ were assessed. Results: results of inter and intra -observer agreement showed an excellent agreement in the different groups. Result of Diagnostic accuracy of CarieScanPRO™ (ICDAS reference) revealed a significant difference (p<0.001) and a moderate statistically significant agreement between both modalities (kappa=0.606). Results of Diagnostic accuracy of CarieScanPRO™ (digital radiography reference) showed a significant difference (p<0.001) and no statistically significant agreement between both modalities (kappa=0.117). Conclusion: The ACIST-based diagnostic modality has great potential for detecting occlusal carious lesions, reducing the risks with radiography.Summary: قد أجريت هذه الدراسة لتقييم الموثوقية لنظام المعاوقة الطيفية الكهربية مقارنة بنتائج الأشعة الرقمية والنظام العالمي الثاني لتحديد التسوس في الكشف عن إصابات التسوس السطحي تم فحص أسطح الإطباق لـ 166 الأسنان الخلفية (الضواحك والضروس) ل 40 مريضًا بالغًا مستوفين لمعايير الأهلية والقبول بواسطة اثنين من المراقبين باستخدام طرق التشخيص المذكورة أعلاه. تم تقييم الأسنان أولاً بالعين المجرّدة بطريقة التقييم الحسّي البصري وفقًا لمعايير النظام الدولي للكشف عن التسوس) اى س دى اس (II ثمّ بواسطة الاشعة السينية الرقمية لنظام المعاوقة الطيفية الكهربية تم قياس التوافق بين المراقبين في طرق التشخيص المذكورة وتمّ تطبيقه احصائيا باستخدام اختبار كابا. كما تم حساب درجة الارتباط بين طريقتي الكشف باستخدام اختبار Shapiro-Wilkوحساب حجم التأثير للمقارنة بين الطرق. تم التقييم الإحصائي لدقة الطرق المستخدمة بالإضافة إلى الدقة التشخيصية، ونسب الاحتمال، واختبارات إحصائية أخرى لكشف التسوس بواسطة الكاميرا المستخدمة. أظهرت نتائج الدراسة الحالية عدم وجود ارتباط إيجابي بين معايير اى س دى اسIIونتائج قياسات نظام المعاوقة الطيفية الكهربية في الكشف عن التسوس السطحي لطبقة العاج (بدقة 82.5 %) و وجود ارتباط ايجاب متوسط ف الكشف عن التسوس السطحي لطبقة المينا (بدقة56.1 %) بينما لم كان هناك ارتباط إيجابي بين نتائج فحص الاشعة السينية الرقمية و نظام المعاوقة الطيفية الكهربية حيث كانت الدقة في الكشف عن تسوس في طبقة المينا (66.7%) و التسوس بطبقة العاج هو (%54.2) فيما يتعلق بكلا المراقبين؛ فقد كان هناك توافق مثالي بينهم لكل طرق الكشف المستخدمة. كما كان هناك اتّساق لدى كل مراقب على حدة في كل الطرق الخلاصة: يعتبر نظام المعاوقة الطيفية الكهربية أداة واعدة لتشخيص التسوس السطحي بالإضافة لتجنب اضرار الاشعة السينية
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Home library Call number Status Barcode
Thesis Thesis قاعة الرسائل الجامعية - الدور الاول المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.09.03.Ph.D.2024.Am.E (Browse shelf(Opens below)) Not for loan 01010110090865000

Browsing المكتبة المركزبة الجديدة - جامعة القاهرة shelves Close shelf browser (Hides shelf browser)

No cover image available
No cover image available
No cover image available
No cover image available
No cover image available
No cover image available
No cover image available
Cai01.09.03.Ph.D.2023.Om.I In Vivo Clinical Evaluation of Dimethyl Sulfoxide Dentin Pre-treatment Prior to a Two-step Etch and Rinse adhesive : Randomized Controlled Trial / Cai01.09.03.Ph.D.2023.Sa.C Clinical evaluation of organically modified ceramic resin composite versus conventional bulkfill resin composite in proximal compound posterior restorations : randomized clinical trial / Cai01.09.03.Ph.D.2024.Ah.C Clinical evaluation of bioactive injectable hybrid resin composite restoration with or without air abrasion surface pretreatment in the repairing capacity of defective composite restoration : Cai01.09.03.Ph.D.2024.Am.E Evaluation of reliability of impedance spectroscopy (cariescan pro™) in comparison with digital radiograph and icdas-ii in detection of occlusal carious lesions : diagnostic accuracy study / Cai01.09.03.Ph.D.2024.Ha.C Clinical evaluation of bioactive injectable resin composite versus conventional nanohybrid composite in posterior restorations,18 m : randomized controlled clinical trial / Cai01.09.03.Ph.D.2024.Is.C Clinical performance of posterior restorations of bulk fill resin composite without preheating versus repeated preheating for one, five and ten times : A randomized controlled clinical trial / Cai01.09.03.Ph.D.2024.Re.C Clinical evaluation of giomer based injectable resin composite versus resin modified glass ionomer in class v carious cavities over 18-months : randomized clinical trial /

Thesis (Ph.D)-Cairo University, 2024.

Bibliography: pages 102-111.

Aim: The aim of this study is to evaluate the Clinical performance of (CarieScanPRO™) in comparison with digital radiograph and ICDAS-II in detection of occlusal carious lesions
Methodology: Occlusal surfaces of 166 posterior teeth were assessed using three diagnostic procedures. 1) (ICDAS-II), 2) digital radiograph, and 3) CarieScanPRO™ device (ACIST). The diagnostic accuracy and 95% CI for caries detection with CarieScanPRO™ were assessed.
Results: results of inter and intra -observer agreement showed an excellent agreement in the different groups. Result of Diagnostic accuracy of CarieScanPRO™ (ICDAS reference) revealed a significant difference (p<0.001) and a moderate statistically significant agreement between both modalities (kappa=0.606). Results of Diagnostic accuracy of CarieScanPRO™ (digital radiography reference) showed a significant difference (p<0.001) and no statistically significant agreement between both modalities (kappa=0.117).
Conclusion: The ACIST-based diagnostic modality has great potential for detecting occlusal carious lesions, reducing the risks with radiography.

قد أجريت هذه الدراسة لتقييم الموثوقية لنظام المعاوقة الطيفية الكهربية مقارنة بنتائج الأشعة الرقمية والنظام العالمي الثاني لتحديد التسوس في الكشف عن إصابات التسوس السطحي
تم فحص أسطح الإطباق لـ 166 الأسنان الخلفية (الضواحك والضروس) ل 40 مريضًا بالغًا مستوفين لمعايير الأهلية والقبول بواسطة اثنين من المراقبين باستخدام طرق التشخيص المذكورة أعلاه. تم تقييم الأسنان أولاً بالعين المجرّدة بطريقة التقييم الحسّي البصري وفقًا لمعايير النظام الدولي للكشف عن التسوس) اى س دى اس (II ثمّ بواسطة الاشعة السينية الرقمية لنظام المعاوقة الطيفية الكهربية
تم قياس التوافق بين المراقبين في طرق التشخيص المذكورة وتمّ تطبيقه احصائيا باستخدام اختبار كابا. كما تم حساب درجة الارتباط بين طريقتي الكشف باستخدام اختبار Shapiro-Wilkوحساب حجم التأثير للمقارنة بين الطرق.
تم التقييم الإحصائي لدقة الطرق المستخدمة بالإضافة إلى الدقة التشخيصية، ونسب الاحتمال، واختبارات إحصائية أخرى لكشف التسوس بواسطة الكاميرا المستخدمة.
أظهرت نتائج الدراسة الحالية عدم وجود ارتباط إيجابي بين معايير اى س دى اسIIونتائج قياسات نظام المعاوقة الطيفية الكهربية في الكشف عن التسوس السطحي لطبقة العاج (بدقة 82.5 %) و وجود ارتباط ايجاب متوسط ف الكشف عن التسوس السطحي لطبقة المينا (بدقة56.1 %) بينما لم كان هناك ارتباط إيجابي بين نتائج فحص الاشعة السينية الرقمية و نظام المعاوقة الطيفية الكهربية حيث كانت الدقة في الكشف عن تسوس في طبقة المينا (66.7%) و التسوس بطبقة العاج هو (%54.2)
فيما يتعلق بكلا المراقبين؛ فقد كان هناك توافق مثالي بينهم لكل طرق الكشف المستخدمة. كما كان هناك اتّساق لدى كل مراقب على حدة في كل الطرق
الخلاصة: يعتبر نظام المعاوقة الطيفية الكهربية أداة واعدة لتشخيص التسوس السطحي بالإضافة لتجنب اضرار الاشعة السينية

Issues also as CD.

Text in English and abstract in Arabic & English.

There are no comments on this title.

to post a comment.
Share
Under the supervision of New Central Library Manager

Implemented and Customized by: Eng.M.Mohamady
Contact:   info@cl.cu.edu.eg

© All rights reserved  New Central Library