header
Image from OpenLibrary

The Effect Of Ips Emax Versus Vita Enamic Superstructure Materials On Implant Stability In Implant Supported Restoration : Randomized Clinical Trial / By Sally Edward Fekry Armol; Supervisors Prof. Dr. Gihan Abdel Hady El Naggar, Dr. Eman Ezzat Youssef.

By: Contributor(s): Material type: TextTextLanguage: English Summary language: English, Arabic Producer: 2023Description: 168 pages : illustrations ; 25 cm. + CDContent type:
  • text
Media type:
  • Unmediated
Carrier type:
  • volume
Other title:
  • تأثير البنية الفوقية المصنعة من أى بى اس إي ماكس مقابل فيتا ايناميك على ثبات الزرعة فى الإستعاضات المدعمة بالزرعة : التجارب السريرية العشوائية [Added title page title]
Subject(s): DDC classification:
  • 617.69
Available additional physical forms:
  • Issued also as CD
Dissertation note: Thesis (Ph.D)-Cairo University, 2023. Summary: Aim: To evaluate the effect of two superstructure materials (all ceramic versus hybrid ceramics) on implant stability, patient satisfaction, crestal bone loss and peri-implant gingival health in implant supported restorations. Methodology: Twenty two single implant supported crowns with either IPS Emax (Group EM) or Vita Enamic crowns (Group VE) were placed in the maxillary premolar region. After osseointegration period (4months post implantation), implants were exposed using a diode laser, cover screws removed and replaced by a healing collar of proper size followed by temporization. Conventional implant closed tray impressions were executed, to determine the exact implant position for fabrication of implant superstructures. The crown retention of the implant superstructures were combined screw and cement retained restorations. This design of the crown was done virtually, using exocad software, after extraoral scanning of the poured casts. The restorations were milled, individualized and stained according to manufacturer’s instructions. Extra-oral cementation using self-cure resin cement of the milled crowns on the titanium abutments, with proper removal of excess cement was accomplished. Implant stability was measured using an OSSTELL implant stability device immediately, 3 months, 6 months, 9 months and 12 months after placement of the crown. After crown placement on the implant, radiographs were taken immediately, 6 months and 12 months after crown placement using CBCT. Peri-implant gingival health (Gingival Index GI, Bleeding Index BI, Probing depth PD) was recorded during the follow up periods given. Patient satisfaction was recorded using a visual analogue scale during the follow up periods allocated. Data were collected, tabulated, and statistically analyzed. Results: Implant stability values demonstrated increase in values with function especially with Vita Enamic crowns, with statistically significant difference between both materials at 12-month follow up interval. Patient satisfaction scores were higher for IPS emax CAD with statistically significant difference at 12-month follow up interval. Clinical peri-implant gingival health assessment (Gingival Index, Bleeding on probing and Probing depth) and radiographic crestal bone loss outcomes owed no statistical difference between both superstructure materials. Conclusion: Vita Enamic crowns presented no negative effect on peri-implant gingival health, crestal bone loss or implant stability, when used to restore implants in the aesthetic zone. Both approaches performed likewise regarding clinical and radiographic parameters. Summary: أثبت استخدام زراعة الأسنان لاستبدال الأسنان المفقودة أنه علاج ناجح. ازداد الاستخدام الروتيني لجميع التركيبات الفوقية للسيراميك بسرعة بسبب التوقعات الجمالية العالية للمريض. اكتسبت جميع التركيبات الفوقية للسيراميك شهرة بسبب جمالياتها الممتازة وتوافقها الحيوي وقوتها العالية. في الآونة الأخيرة ، تم استخدام كتل السيراميك المتسربة من البوليمر مثل Vita Enamic كتيجان مدعومة بزرع واحد بسبب مرونتها وتأثير امتصاص الصدمات. تم تقييم الدراسة الحالية في الجسم الحي ، واستقرار الغرسة ، ورضا المريض ، ومعايير صحة اللثة ، ومستوى عظم القشرة من مادتين من البنية الفوقية في منطقة الضواحك الفكي العلوي(IPS emax , Vita Enamic). تم تصنيع 22 تاجًا مدعومًا بغرس واحد باستخدام مادتين مختلفتين من السيراميك. حسب نوع المادة تم تقسيم المرضى إلى مجموعتين. المجموعة EM: مادة خزفية ليثيوم ثنائي سيليكات (IPS emax). المجموعة VE: مادة خزفية متسللة من البوليمر (Vita Enamic). بعد تثبيت التيجان على دعامات التيتانيوم المقابلة لها ، تم تقييم ثبات الغرسة باستخدام جهاز قياس ثبات غرسة Osstell .تم تسجيل رضا المريض باستخدام مقياس تناظري بصري (VAS). متغيرات صحة اللثة حول الزرع التي تم تقييمها شملت درجة مؤشر اللثة ، والنزيف على درجة السبر وقياس عمق سبر التلم. أخيرًا ، تم قياس مستوى العظم عن طريق CBCT خلال فترات المتابعة لتحديد مقدار فقدان العظم القماعي حول كل غرسة. بناءً على نتائج الدراسة الحالية وضمن حدودها ، تم استنتاج أنه لا يوجد فرق مهم بين كل من مواد البنية الفوقية عند استخدامها كغرس واحد مدعوم بتاج في منطقة الضاحك العلوي.
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Home library Call number Status Barcode
Thesis Thesis قاعة الرسائل الجامعية - الدور الاول المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.09.09.Ph.D.2023.Sa.E. (Browse shelf(Opens below)) Not for loan 01010110091073000

Thesis (Ph.D)-Cairo University, 2023.

Bibliography: pages 200-250.

Aim: To evaluate the effect of two superstructure materials (all ceramic versus hybrid ceramics) on implant stability, patient satisfaction, crestal bone loss and peri-implant gingival health in implant supported restorations.
Methodology: Twenty two single implant supported crowns with either IPS Emax (Group EM) or Vita Enamic crowns (Group VE) were placed in the maxillary premolar region. After osseointegration period (4months post implantation), implants were exposed using a diode laser, cover screws removed and replaced by a healing collar of proper size followed by temporization. Conventional implant closed tray impressions were executed, to determine the exact implant position for fabrication of implant superstructures. The crown retention of the implant superstructures were combined screw and cement retained restorations. This design of the crown was done virtually, using exocad software, after extraoral scanning of the poured casts. The restorations were milled, individualized and stained according to manufacturer’s instructions. Extra-oral cementation using self-cure resin cement of the milled crowns on the titanium abutments, with proper removal of excess cement was accomplished. Implant stability was measured using an OSSTELL implant stability device immediately, 3 months, 6 months, 9 months and 12 months after placement of the crown. After crown placement on the implant, radiographs were taken immediately, 6 months and 12 months after crown placement using CBCT. Peri-implant gingival health (Gingival Index GI, Bleeding Index BI, Probing depth PD) was recorded during the follow up periods given. Patient satisfaction was recorded using a visual analogue scale during the follow up periods allocated. Data were collected, tabulated, and statistically analyzed.
Results: Implant stability values demonstrated increase in values with function especially with Vita Enamic crowns, with statistically significant difference between both materials at 12-month follow up interval. Patient satisfaction scores were higher for IPS emax CAD with statistically significant difference at 12-month follow up interval. Clinical peri-implant gingival health assessment (Gingival Index, Bleeding on probing and Probing depth) and radiographic crestal bone loss outcomes owed no statistical difference between both superstructure materials.
Conclusion: Vita Enamic crowns presented no negative effect on peri-implant gingival health, crestal bone loss or implant stability, when used to restore implants in the aesthetic zone. Both approaches performed likewise regarding clinical and radiographic parameters.

أثبت استخدام زراعة الأسنان لاستبدال الأسنان المفقودة أنه علاج ناجح. ازداد الاستخدام الروتيني لجميع التركيبات الفوقية للسيراميك بسرعة بسبب التوقعات الجمالية العالية للمريض. اكتسبت جميع التركيبات الفوقية للسيراميك شهرة بسبب جمالياتها الممتازة وتوافقها الحيوي وقوتها العالية. في الآونة الأخيرة ، تم استخدام كتل السيراميك المتسربة من البوليمر مثل Vita Enamic كتيجان مدعومة بزرع واحد بسبب مرونتها وتأثير امتصاص الصدمات.
تم تقييم الدراسة الحالية في الجسم الحي ، واستقرار الغرسة ، ورضا المريض ، ومعايير صحة اللثة ، ومستوى عظم القشرة من مادتين من البنية الفوقية في منطقة الضواحك الفكي العلوي(IPS emax , Vita Enamic).
تم تصنيع 22 تاجًا مدعومًا بغرس واحد باستخدام مادتين مختلفتين من السيراميك. حسب نوع المادة تم تقسيم المرضى إلى مجموعتين. المجموعة EM: مادة خزفية ليثيوم ثنائي سيليكات (IPS emax). المجموعة VE: مادة خزفية متسللة من البوليمر (Vita Enamic).
بعد تثبيت التيجان على دعامات التيتانيوم المقابلة لها ، تم تقييم ثبات الغرسة باستخدام جهاز قياس ثبات غرسة Osstell .تم تسجيل رضا المريض باستخدام مقياس تناظري بصري (VAS). متغيرات صحة اللثة حول الزرع التي تم تقييمها شملت درجة مؤشر اللثة ، والنزيف على درجة السبر وقياس عمق سبر التلم. أخيرًا ، تم قياس مستوى العظم عن طريق CBCT خلال فترات المتابعة لتحديد مقدار فقدان العظم القماعي حول كل غرسة.
بناءً على نتائج الدراسة الحالية وضمن حدودها ، تم استنتاج أنه لا يوجد فرق مهم بين كل من مواد البنية الفوقية عند استخدامها كغرس واحد مدعوم بتاج في منطقة الضاحك العلوي.

Issued also as CD

Text in English and abstract in Arabic & English.

There are no comments on this title.

to post a comment.
Under the supervision of New Central Library Manager

Implemented and Customized by: Eng.M.Mohamady
Contact:   info@cl.cu.edu.eg

© All rights reserved  New Central Library