Design and implementation of a system based on Nd:Yag (266 nm) for laser corneal reshaping compared with existing technology with ArF excimer laser (193 nm) / By Ibrahim Nabil Fargal Abdelhalim; Under the Supervision of Assoc. Prof. Dr. Salah Hassab-Elnaby, Assoc. Prof. Dr. Omnia Hamdy, Assoc. Prof. Dr. Aziza Ahmed Hassan, Prof. Dr. Salwa Abdelkawi

By: Contributor(s): Material type: TextLanguage: English Summary language: English, Arabic Producer: 2024Description: 98 pages : illustrations ; 25 cm. + CDContent type:
  • text
Media type:
  • Unmediated
Carrier type:
  • volume
Other title:
  • تصميم و تنفيذ نظام يعتمد على ليزر النودينموم ياج (266 نانومتير) لاعاده تشكيل القرنيه مقارنه مع التكنولوجيا الحاليه التى تستخدم الاكزيمر ليزر الارجون فلوريد (193 نانوميتر) [Added title page title]
Subject(s): DDC classification:
  • 621.366
Available additional physical forms:
  • Issued also as CD
Dissertation note: Thesis (Ph.D)-Cairo University, 2024. Summary: In the current work, laser system (266-nm) was designed, implemented and compared with existing technology with ArF excimer laser (193-nm). For system evaluation, different pulse energies were applied with the same number of shoots to ex-vivo rabbit corneas and the histological effect was investigated and also electron microscope study. Additionally, the DNA was evaluated using the Comet test. Also thermal camera investigated the thermal effect on the cornea as well as Fourier transform infrared (FTIR). Moreover, we employed 3D mathematical model. Finally, results showed it can be alternative to (193-nm)Summary: تم فى هذه الدراسه الاتى تقييم فعاليه التاثير الاجتثاثى للطول الموجى266 نانومتر تحت المجهر الإلكتروني على قرنية الأرانب خارج الجسم الحي ونم عمل مقارنه بين التاثير الاجتثاثى من خلال التحليل الطيفي بالأشعة تحت الحمراء بتحويل فورييه و تقيم التاثير على مكونات الجزيئات للقرنيه وتم تطوير مسار لليزر لعمل عمليات اعاده تشكيل سطح القرنيه وتطبيقها على قرنيه ارنب داخل الجسم و تقيم فعاليه العمليه دراسه الاجزاء الناتجه من عمليه الاجتثاث الضوى تقيم التاثير الحرارى للطول الموجى 266 نانومتر عن طريق نموذج رياضى و خلصت النتائج ان الليزر ذات الطول الموجى 266 نانو ميتر قد يكون بديل فعال للالليزر ذات الطول الموجى 193 نانو ميتر
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)

Thesis (Ph.D)-Cairo University, 2024.

Bibliography: pages 84-97.

In the current work, laser system (266-nm) was designed, implemented and compared with existing technology with ArF excimer laser (193-nm). For system evaluation, different pulse energies were applied with the same number of shoots to ex-vivo rabbit corneas and the histological effect was investigated and also electron microscope study. Additionally, the DNA was evaluated using the Comet test. Also thermal camera investigated the thermal effect on the cornea as well as Fourier transform infrared (FTIR). Moreover, we employed 3D mathematical model. Finally, results showed it can be alternative to (193-nm)

تم فى هذه الدراسه الاتى تقييم فعاليه التاثير الاجتثاثى للطول الموجى266 نانومتر تحت المجهر الإلكتروني على قرنية الأرانب خارج الجسم الحي ونم عمل مقارنه بين التاثير الاجتثاثى من خلال التحليل الطيفي بالأشعة تحت الحمراء بتحويل فورييه و تقيم التاثير على مكونات الجزيئات للقرنيه وتم تطوير مسار لليزر لعمل عمليات اعاده تشكيل سطح القرنيه وتطبيقها على قرنيه ارنب داخل الجسم و تقيم فعاليه العمليه دراسه الاجزاء الناتجه من عمليه الاجتثاث الضوى تقيم التاثير الحرارى للطول الموجى 266 نانومتر عن طريق نموذج رياضى و خلصت النتائج ان الليزر ذات الطول الموجى 266 نانو ميتر قد يكون بديل فعال للالليزر ذات الطول الموجى 193 نانو ميتر

Issued also as CD

Text in English and abstract in Arabic & English.

There are no comments on this title.

to post a comment.
Share
Cairo University Libraries Portal Implemented & Customized by: Eng. M. Mohamady Contacts: new-lib@cl.cu.edu.eg | cnul@cl.cu.edu.eg
CUCL logo CNUL logo
© All rights reserved — Cairo University Libraries
CUCL logo
Implemented & Customized by: Eng. M. Mohamady Contact: new-lib@cl.cu.edu.eg © All rights reserved — New Central Library
CNUL logo
Implemented & Customized by: Eng. M. Mohamady Contact: cnul@cl.cu.edu.eg © All rights reserved — Cairo National University Library