Image from OpenLibrary

Marginal adaptation and internal fit of advanced lithium disilicate (tessera) versus lithium disilicate (ips-emax cad) implant-supported hybrid abutment crowns : an invitro study / by Yara Hossam El-Deen Salama El-Kady ; Supervision Prof.Hanaa Ibraheem Sallam, Prof. Hayat Ibrahim Mahrous.

By: Contributor(s): Material type: TextLanguage: English Summary language: English, Arabic Producer: 2025Description: 102 pages : illustrations ; 25 cm. + CDContent type:
  • text
Media type:
  • Unmediated
Carrier type:
  • volume
Other title:
  • الدقه الحافية والملائمة الداخلية للتيجان ذات الدعامات الهجينه المحمله علی الغرسات و المصنعه من ثنائي سيليكات الليثيوم المتطوره (تيسيرا) مقارنه بثنائي سيليكات الليثيوم (أي بي اس ايماكس) : دراسة معملية [Added title page title]
Subject(s): DDC classification:
  • 617.692
Available additional physical forms:
  • Issues also as CD.
Dissertation note: Thesis (M.Sc)-Cairo University, 2025. Summary: Aim: The purpose of this study was to evaluate the marginal gap and internal fit of implant-supported hybrid abutment crowns (HACs) fabricated from advanced lithium disilicate (CEREC Tessera) and lithium disilicate (IPS e.max CAD). Materials and Methods: A total of twenty-four HACs with custom-milled screw channels were fabricated using a digital workflow from CEREC Tessera and IPS e.max CAD (n=12 per group). Marginal adaptation was assessed using a stereomicroscope, while the internal fit was evaluated using the replica technique. Data were collected and statistically analyzed. Results: A statistically significant difference was observed between the two groups in terms of marginal adaptation (P=0.001), where CEREC Tessera exhibited a lower marginal gap. However, no statistically significant difference was found between the two groups regarding internal fit (P=0.056). Conclusion: Both CEREC Tessera and IPS e.max CAD hybrid abutment crowns demonstrated clinically acceptable marginal adaptation and internal fit within the established clinical values. Notably, CEREC Tessera showed significantly superior marginal adaptation compared to IPS e.max CAD. Summary: هدفت هذه الدراسة إلى تقييم الدقة الحافية والملائمة الداخلية للتيجان ذات الدعامات الهجينة المحملة على الغرسات والمصنوعة من مادتي ثنائي سيليكات الليثيوم: سيريك تيسيرا و آي بي إس إي ماكس. تم تصنيع 24 تاجًا ذو دعامات هجينه مع قنوات مسامير مخصصة باستخدام التقنية الرقمية بالكامل، وتم تخصيص 12 تاجًا لكل مجموعة. تم تقييم الدقة الحافية باستخدام المجهر الالكتروني (الاستريو)، بينما تم قياس الملائمة الداخلية باستخدام تقنية الطبعة المتماثلة وشملت التحليلات الإحصائية اختبارات التوزيع الطبيعي تلاها اختبار تحديد مستوي الدلالة (P<0.05). أظهرت النتائج وجود فرق إحصائي في الدقة الحافية بين المجموعتين (P=0.001)، حيث سجلت مجموعة سيريك تيسيرا فجوة حافية أقل.، ولم يكن هناك فرق ذو دلالة إحصائية بين المجموعتين فيما يتعلق بالملائمة الداخلية (P=0.056). في حدود هذه الدراسة، كلتا المادتين أظهرتا تكيفًا حافيًا وملائمه داخليه ضمن الحدود المقبولة سريريًا، وضمن النطاقات المذكورة في الأبحاث العلمية، تدعم هذه النتائج استخدام المادتين في الترميمات المدعومة بالزرعات.
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Home library Call number Status Barcode
Thesis قاعة الرسائل الجامعية - الدور الاول المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.09.09.M.Sc.2025.Ya.M (Browse shelf(Opens below)) Not for loan 01010110093275000

Thesis (M.Sc)-Cairo University, 2025.

Bibliography: pages 91-100.

Aim: The purpose of this study was to evaluate the marginal gap and internal fit of implant-supported
hybrid abutment crowns (HACs) fabricated from advanced lithium disilicate (CEREC Tessera) and
lithium disilicate (IPS e.max CAD).
Materials and Methods: A total of twenty-four HACs with custom-milled screw channels were
fabricated using a digital workflow from CEREC Tessera and IPS e.max CAD (n=12 per group).
Marginal adaptation was assessed using a stereomicroscope, while the internal fit was evaluated using
the replica technique. Data were collected and statistically analyzed.

Results: A statistically significant difference was observed between the two groups in terms of
marginal adaptation (P=0.001), where CEREC Tessera exhibited a lower marginal gap. However, no
statistically significant difference was found between the two groups regarding internal fit (P=0.056).

Conclusion: Both CEREC Tessera and IPS e.max CAD hybrid abutment crowns demonstrated
clinically acceptable marginal adaptation and internal fit within the established clinical values.
Notably, CEREC Tessera showed significantly superior marginal adaptation compared to IPS e.max
CAD.

هدفت هذه الدراسة إلى تقييم الدقة الحافية والملائمة الداخلية للتيجان ذات الدعامات الهجينة المحملة على الغرسات والمصنوعة من مادتي ثنائي سيليكات الليثيوم: سيريك تيسيرا و آي بي إس إي ماكس.
تم تصنيع 24 تاجًا ذو دعامات هجينه مع قنوات مسامير مخصصة باستخدام التقنية الرقمية بالكامل، وتم تخصيص 12 تاجًا لكل مجموعة. تم تقييم الدقة الحافية باستخدام المجهر الالكتروني (الاستريو)، بينما تم قياس الملائمة الداخلية باستخدام تقنية الطبعة المتماثلة وشملت التحليلات الإحصائية اختبارات التوزيع الطبيعي تلاها اختبار تحديد مستوي الدلالة (P<0.05).
أظهرت النتائج وجود فرق إحصائي في الدقة الحافية بين المجموعتين (P=0.001)، حيث سجلت مجموعة سيريك تيسيرا فجوة حافية أقل.، ولم يكن هناك فرق ذو دلالة إحصائية بين المجموعتين فيما يتعلق بالملائمة الداخلية (P=0.056).
في حدود هذه الدراسة، كلتا المادتين أظهرتا تكيفًا حافيًا وملائمه داخليه ضمن الحدود المقبولة سريريًا، وضمن النطاقات المذكورة في الأبحاث العلمية، تدعم هذه النتائج استخدام المادتين في الترميمات المدعومة بالزرعات.

Issues also as CD.

Text in English and abstract in Arabic & English.

There are no comments on this title.

to post a comment.
Share
Cairo University Libraries Portal Implemented & Customized by: Eng. M. Mohamady Contacts: new-lib@cl.cu.edu.eg | cnul@cl.cu.edu.eg
CUCL logo CNUL logo
© All rights reserved — Cairo University Libraries
CUCL logo
Implemented & Customized by: Eng. M. Mohamady Contact: new-lib@cl.cu.edu.eg © All rights reserved — New Central Library
CNUL logo
Implemented & Customized by: Eng. M. Mohamady Contact: cnul@cl.cu.edu.eg © All rights reserved — Cairo National University Library