The effect of manufacturing technique, storage and sterilization on the accuracy of computer aided implant surgical guides : An Invitro study =تأثير طرق الصناعة المختلفة التخزين و التعقيم على دقة الادلة الجراحية للغرسات بمساعدة الكمبيوتر : دراسة معمليه / Mahetab Hamdi Abdelfatah ; Supervised Ashraf Abdelmonem Amer , Amr Hosny Elkhadem
نوع المادة :
نصاللغة: الإنجليزية تفاصيل النشر: Cairo : Mahetab Hamdi Abdelfatah , 2016الوصف: 109 : charts , photographs ; 25cmعنوان آخر: - تأثير طرق الصناعة المختلفة ، التخزين و التعقيم على دقة الادلة الجراحية للغرسات بمساعدة الكمبيوتر : دراسة معمليه [عنوان مضاف عنوان الصفحة]
- Issued also as CD
| نوع المادة | المكتبة الحالية | المكتبة الرئيسية | رقم الاستدعاء | رقم النسخة | حالة | الباركود | |
|---|---|---|---|---|---|---|---|
Thesis
|
قاعة الرسائل الجامعية - الدور الاول | المكتبة المركزبة الجديدة - جامعة القاهرة | Cai01.09.09.M.Sc.2016.Ma.E (استعراض الرف(يفتح أدناه)) | لا تعار | 01010110072710000 | ||
CD - Rom
|
مخـــزن الرســائل الجـــامعية - البدروم | المكتبة المركزبة الجديدة - جامعة القاهرة | Cai01.09.09.M.Sc.2016.Ma.E (استعراض الرف(يفتح أدناه)) | 72710.CD | لا تعار | 01020110072710000 |
استعرض المكتبة المركزبة الجديدة - جامعة القاهرة رفاً إغلاق مستعرض الرف (يخفي مستعرض الرف)
Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Prosthodontics
This invitro study was designed to compare the effect of four manufacturing techniques, storage, chemical sterilization and autoclaving on accuracy of computer guided surgical guides. An impression for class III Kennedy classification partially edentulous case was made and poured into epoxy resin to construct a cast. The cast was laser scanned and a surgical guide was designed by the Blue sky software for implant planning. Four techniques were used for manufacturing which were SLS, milling, SLA and FDM. Measuring accuracy were done in three terms; evaluation of sleeve hole tolerance, guide adaptation and accuracy of sleeve angle. The sleeve hole tolerance was evaluated by special customized metal cylinders of different diameters where each diameter was used to evaluate its fit inside the sleeve hole. For the microgap photos were captured by digital microscope and then analyzed by image J software. Regarding angular deviation, laser scanning of the surgical guide with special customized metal cylinders both were sealed on the model was done then evaluating of angular deviation was carried by blue sky..The accuracy was measured in five phases after 24 hour of manufacturing, one week storage, two week storage, chemical sterilization and autoclaving. All results were tabulated and analyzed to reach conclusion