Assessment of the accuracy of surgical guide designed from cbct with different voxel sizes in computer guided implantology : Randomized clinical trial / Mohammed Mohammed Ahmed Elhag ; Supervised Mushira M. Dahaba , Ahmed M. Abdalsamad
Material type:
TextLanguage: English Publication details: Cairo : Mohammed Mohammed Ahmed Elhag Ibrahim , 2019Description: 72 P. : charts , photographs ; 25cmOther title: - تقييم دقة الدليل الجراحى المصمم من التصوير المقطعى بالحاسوب مخروطى الشعاع باستخدام عناصر حجمية مختلفة فى زرع الأسنان بمعاونة الحاسوب : تجربة سريرية عشوائية [Added title page title]
- Issued also as CD
| Item type | Current library | Home library | Call number | Copy number | Status | Barcode | |
|---|---|---|---|---|---|---|---|
Thesis
|
قاعة الرسائل الجامعية - الدور الاول | المكتبة المركزبة الجديدة - جامعة القاهرة | Cai01.09.13.M.Sc.2019.Mo.A (Browse shelf(Opens below)) | Not for loan | 01010110079975000 | ||
CD - Rom
|
مخـــزن الرســائل الجـــامعية - البدروم | المكتبة المركزبة الجديدة - جامعة القاهرة | Cai01.09.13.M.Sc.2019.Mo.A (Browse shelf(Opens below)) | 79975.CD | Not for loan | 01020110079975000 |
Browsing المكتبة المركزبة الجديدة - جامعة القاهرة shelves Close shelf browser (Hides shelf browser)
Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Oral and Maxillofacial Surgery
Objectives:The present study was designed to assess the effect of CBCT with different voxel sizes on the accuracy of surgical guide fabrication on computer guided implantolog. Material and methods:This study was conducted on eight patients selected from outpatient clinic, Faculty of dentistry, Cairo university. The patients were divided into two groups. One group received dental implants using surgical guides designed from CBCT with 0.2 mm voxel size while the other group received dental implants using surgical guides designed from CBCT with 0.4 mm voxel size. The surgical guides were designed using bluesky bio software. The patients were asked for post-operative CBCT to compare the accuracy the surgical guide. Linear and angular deviations were measured between planned and actual position in both groups. The results were tabulated and statistically analyze.Results:Surgical guides manufactured with CBCT of 0.2 mm voxel size showed statistically significantly lower median linear and angular deviation than surgical guides manufactured with CBCT of 0.4 mm voxel in BL direction. While there was no statistically significantly difference between the two groups in linear and angular deviation in MD direction. Conclusion: There was no clinical significantly clinical difference in linear and angular accuracy between surgical guides manufactured from CBCT with voxel size either 0.2mm or 0.4 mm
Issued also as CD
There are no comments on this title.