Image from OpenLibrary

Effect of cbct dose reduction on the mandibular canal visibility compared to standard cbct dose : Diagnostic accuracy study / By Mai Mostafa Shaldoum; Supervisors Prof. Dr. Reham Mohamed Hamdy, Dr. Hala Wafik El Fayoumy.

By: Contributor(s): Material type: TextLanguage: English Summary language: English, Arabic Producer: 2024Description: 122 pages : illustrations ; 25 cm. + CDContent type:
  • text
Media type:
  • Unmediated
Carrier type:
  • volume
Other title:
  • تأثير خفض الجرعة الاشعاعية للأشعة المقطعية بالحاسوب مخروطية الشعاع على رؤية قناة الفك السفلي مقارنة بجرعة الاشعة المقطعية مخروطية الشعاع القياسية : دراسة دقة تشخيصية [Added title page title]
Subject(s): DDC classification:
  • 617.605
Available additional physical forms:
  • Issued also as CD
Dissertation note: Thesis (M.Sc.)-Cairo University, 2024. Summary: Aim: To assess the diagnostic accuracy of cone-beam computed tomography (CBCT) dose reduction on the mandibular canal visibility compared to standard CBCT dose, in cases requiring assessment of mandibular canal to plan conservative or radical treatment in the mandibular posterior region. Methodology: Ten human dry mandibles were scanned six times using a Planmeca ProMax® 3D Mid CBCT machine, employing three conventional CBCT protocols and three ultra-low CBCT protocols. Varying combinations of milliampere-second (mAs) and voxel size values were utilized across these protocols. The clarity of mandibular canal visibility was evaluated using a two-scale scoring system, comparing an ultra-low dose protocol (42.6 mAs/0.2 mm) to the gold standard protocol (180 mAs/0.2 mm). Additionally, the degree of mandibular canal visibility was assessed using a five-scale scoring system, comparing three ultra-low dose protocols (42.6 mAs/0.2 mm, 25.2 mAs/0.4 mm, and 9.9 mAs/0.6 mm) and two conventional protocols (108 mAs/0.4 mm and 50.4 mAs/0.6 mm) to the gold standard protocol. Gutta-percha points were used as reference markers to standardize the area under investigation. Comparative analysis was conducted on 2-dimensional trans-axial images by two observers. Results: The results showed that an ultra-low dose protocol (42.6 mAs/0.2 mm) achieved similar clarity to the standard dose (180 mAs/0.2 mm) when using a simple two-point scoring systemHowever, a more detailed five-point scale revealed significant differences, with higher milliampere-seconds (mAs) and smaller voxel sizes leading to better visibility scores. Importantly, inter-observer agreement remained good for both scoring methods. Conclusion: Ultra-low dose CBCT appears to be a viable option for tasks requiring clear visualization of the mandibular canal. While standard dose protocol might be preferable for situations demanding more precise canal definition, this study suggests the potential for CBCT dose reduction in clinical applications requiring MC visualization, potentially enabling more conservative treatment approaches.Summary: تعد قناة الفك السفلي (MC) جزء حساس في عظم الفك تحتوي على الأعصاب والأوعية الدموية. يعد تحديد موقعها بدقة أمرا ضروريا لعلاج اّمن و فعال في الجزء الخلفي من الفك السفلي . التصوير المقطعي بالأشعة السينية بكمبيوتر الشعاع المخروطي (CBCT) هو طريقة تصوير قيمة لهذا الغرض ، ولكنه يتضمن أيضًا التعرض للإشعاع. بحثت هذه الأطروحة في تأثير تقليل جرعة CBCT على رؤية قناة الفك السفلي. بحثت هذه الدراسة في فعالية التصوير المقطعي بالأشعة السينية بكمبيوتر الشعاع المخروطي (CBCT) بجرعة منخفضة للغاية مقارنة بالجرعة القياسية لتوضيح قناة الفك السفلي في عظام الفك البشرية الجافة. قام جهاز Planmeca ProMax® 3D Mid بإنشاء فحوصات CBCT باستخدام إعدادات تعرض لجرعات أشعه مختلفة. كان السؤال الأساسي هو ما إذا كانت جرعات CBCT المنخفضة تؤثر على رؤية قناة الفك السفلي (MC) عند مقارنتها بالجرعة القياسية. تم تحضير عشرة من عظام الفك السفلي بشكل دقيق لمحاكاة ظروف الأنسجة الرخوة في جسم الانسان. خضعت صور CBCT الناتجة لتحليل تفصيلي باستخدام برنامج. Romexis® استخدم الباحثون نظامي تقييم لتقييم كل من وضوح (واضح مقابل غير واضح) ومستوى دقة تفاصيل قناة الفك السفلي. بالإضافة إلى ذلك ، تم ضمان موثوقية التفسير من خلال تقييم اتفاق كل من المراقبين والمراقب الواحد.
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Home library Call number Status Barcode
Thesis قاعة الرسائل الجامعية - الدور الاول المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.09.05.M.Sc.2024.Ma.E. (Browse shelf(Opens below)) Not for loan 01010110090938000

Thesis (M.Sc.)-Cairo University, 2024.

Bibliography: pages 106-119.

Aim: To assess the diagnostic accuracy of cone-beam computed tomography (CBCT) dose reduction on the mandibular canal visibility compared to standard CBCT dose, in cases requiring assessment of mandibular canal to plan conservative or radical treatment in the mandibular posterior region.
Methodology: Ten human dry mandibles were scanned six times using a Planmeca ProMax® 3D Mid CBCT machine, employing three conventional CBCT protocols and three ultra-low CBCT protocols. Varying combinations of milliampere-second (mAs) and voxel size values were utilized across these protocols. The clarity of mandibular canal visibility was evaluated using a two-scale scoring system, comparing an ultra-low dose protocol (42.6 mAs/0.2 mm) to the gold standard protocol (180 mAs/0.2 mm). Additionally, the degree of mandibular canal visibility was assessed using a five-scale scoring system, comparing three ultra-low dose protocols (42.6 mAs/0.2 mm, 25.2 mAs/0.4 mm, and 9.9 mAs/0.6 mm) and two conventional protocols (108 mAs/0.4 mm and 50.4 mAs/0.6 mm) to the gold standard protocol. Gutta-percha points were used as reference markers to standardize the area under investigation. Comparative analysis was conducted on 2-dimensional trans-axial images by two observers. Results: The results showed that an ultra-low dose protocol (42.6 mAs/0.2 mm) achieved similar clarity to the standard dose (180 mAs/0.2 mm) when using a simple two-point scoring systemHowever, a more detailed five-point scale revealed significant differences, with higher milliampere-seconds (mAs) and smaller voxel sizes leading to better visibility scores. Importantly, inter-observer agreement remained good for both scoring methods.
Conclusion: Ultra-low dose CBCT appears to be a viable option for tasks requiring clear visualization of the mandibular canal. While standard dose protocol might be preferable for situations demanding more precise canal definition, this study suggests the potential for CBCT dose reduction in clinical applications requiring MC visualization, potentially enabling more conservative treatment approaches.

تعد قناة الفك السفلي (MC) جزء حساس في عظم الفك تحتوي على الأعصاب والأوعية الدموية. يعد تحديد موقعها بدقة أمرا ضروريا لعلاج اّمن و فعال في الجزء الخلفي من الفك السفلي . التصوير المقطعي بالأشعة السينية بكمبيوتر الشعاع المخروطي (CBCT) هو طريقة تصوير قيمة لهذا الغرض ، ولكنه يتضمن أيضًا التعرض للإشعاع. بحثت هذه الأطروحة في تأثير تقليل جرعة CBCT على رؤية قناة الفك السفلي. بحثت هذه الدراسة في فعالية التصوير المقطعي بالأشعة السينية بكمبيوتر الشعاع المخروطي (CBCT) بجرعة منخفضة للغاية مقارنة بالجرعة القياسية لتوضيح قناة الفك السفلي في عظام الفك البشرية الجافة. قام جهاز Planmeca ProMax® 3D Mid بإنشاء فحوصات CBCT باستخدام إعدادات تعرض لجرعات أشعه مختلفة. كان السؤال الأساسي هو ما إذا كانت جرعات CBCT المنخفضة تؤثر على رؤية قناة الفك السفلي (MC) عند مقارنتها بالجرعة القياسية. تم تحضير عشرة من عظام الفك السفلي بشكل دقيق لمحاكاة ظروف الأنسجة الرخوة في جسم الانسان. خضعت صور CBCT الناتجة لتحليل تفصيلي باستخدام برنامج. Romexis® استخدم الباحثون نظامي تقييم لتقييم كل من وضوح (واضح مقابل غير واضح) ومستوى دقة تفاصيل قناة الفك السفلي. بالإضافة إلى ذلك ، تم ضمان موثوقية التفسير من خلال تقييم اتفاق كل من المراقبين والمراقب الواحد.

Issued also as CD

Text in English and abstract in English.

There are no comments on this title.

to post a comment.
Share
Cairo University Libraries Portal Implemented & Customized by: Eng. M. Mohamady Contacts: new-lib@cl.cu.edu.eg | cnul@cl.cu.edu.eg
CUCL logo CNUL logo
© All rights reserved — Cairo University Libraries
CUCL logo
Implemented & Customized by: Eng. M. Mohamady Contact: new-lib@cl.cu.edu.eg © All rights reserved — New Central Library
CNUL logo
Implemented & Customized by: Eng. M. Mohamady Contact: cnul@cl.cu.edu.eg © All rights reserved — Cairo National University Library