Oral health related quality of life and peri-implant condition in single implant mandibular overdenture retained by CM LOC versus ball attachment : A randomized controlled trial / Marwa Abdelaal Mohammed ; Supervised Mahmoud Mokhtar Elfar , Nora Mohamed Cheta , Ahmed Emad Fayyad

By: Contributor(s): Material type: TextLanguage: English Publication details: Cairo : Marwa Abdelaal Mohammed , 2019Description: 120 P. : charts , facsimiles ; 25cmOther title:
  • و المرفق الكروى CM LOC جودة الحياة المرتبطة بصحة الفم و تفاعل الانسجة الرخوة فى الاطقم المحملة على زرعة واحدة باستخدام مرفق : تجربة سريرية عشوائية [Added title page title]
Subject(s): Online resources: Available additional physical forms:
  • Issued also as CD
Dissertation note: Thesis (Ph.D.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Prosthodontics Summary: Single implant mandibular overdenture had been reported to achieve satisfactory patient centered results. Two groups (Ball and CM LOC attachments) were chosen to retain the over-denture. 30 subjects were recruited for non-submerged healing protocol. Implants were installed based on CBCT planning and after patients{u2019} approval confirmed by a written consent. A healing cap was left for three months after which randomization was done prior to attachment pick up to select from either ball or CM LOC attachments OHIP-EDENT which is a type of oral health related quality of life and peri-implant soft tissue reactions were reported at 3,6,9, &12 months interval of time. Results had shown statistically insignificant results between the two groups regarding the OHRQOL although CM LOC attachment had expressed relatively higher satisfaction compared to ball. Regarding soft tissue reactions, gingival inflammation and plaque accumulation were more observed around and over ball respectively. expressing relatively worse results than that of CM LOC attachment. The results for the different domains of the OHRQOL suggested that the replacement of CDs with mandibular overdentures retained by a single implant caused immediate improvements in decreased oral pain and discomfort, late improvement in oral function (mastication), and no influences on physiological or social aspects of discomfort or disability over a 1-year period regardless of the attachment type
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Home library Call number Copy number Status Barcode
Thesis قاعة الرسائل الجامعية - الدور الاول المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.09.09.Ph.D.2019.Ma.O (Browse shelf(Opens below)) Not for loan 01010110080168000
CD - Rom مخـــزن الرســائل الجـــامعية - البدروم المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.09.09.Ph.D.2019.Ma.O (Browse shelf(Opens below)) 80168.CD Not for loan 01020110080168000

Thesis (Ph.D.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Prosthodontics

Single implant mandibular overdenture had been reported to achieve satisfactory patient centered results. Two groups (Ball and CM LOC attachments) were chosen to retain the over-denture. 30 subjects were recruited for non-submerged healing protocol. Implants were installed based on CBCT planning and after patients{u2019} approval confirmed by a written consent. A healing cap was left for three months after which randomization was done prior to attachment pick up to select from either ball or CM LOC attachments OHIP-EDENT which is a type of oral health related quality of life and peri-implant soft tissue reactions were reported at 3,6,9, &12 months interval of time. Results had shown statistically insignificant results between the two groups regarding the OHRQOL although CM LOC attachment had expressed relatively higher satisfaction compared to ball. Regarding soft tissue reactions, gingival inflammation and plaque accumulation were more observed around and over ball respectively. expressing relatively worse results than that of CM LOC attachment. The results for the different domains of the OHRQOL suggested that the replacement of CDs with mandibular overdentures retained by a single implant caused immediate improvements in decreased oral pain and discomfort, late improvement in oral function (mastication), and no influences on physiological or social aspects of discomfort or disability over a 1-year period regardless of the attachment type

Issued also as CD

There are no comments on this title.

to post a comment.

Click on an image to view it in the image viewer

Local cover image
Share
Cairo University Libraries Portal Implemented & Customized by: Eng. M. Mohamady Contacts: new-lib@cl.cu.edu.eg | cnul@cl.cu.edu.eg
CUCL logo CNUL logo
© All rights reserved — Cairo University Libraries
CUCL logo
Implemented & Customized by: Eng. M. Mohamady Contact: new-lib@cl.cu.edu.eg © All rights reserved — New Central Library
CNUL logo
Implemented & Customized by: Eng. M. Mohamady Contact: cnul@cl.cu.edu.eg © All rights reserved — Cairo National University Library