header

Effect of different locator attachment on retention of implant retained overdenture on distally inclined implants : An in vitro study /

Rani Mohamed Alzinati

Effect of different locator attachment on retention of implant retained overdenture on distally inclined implants : An in vitro study / تأثير الوصلات الموضعية المختلفة على استبقاء الأطقم المحمولة على غرسات مائلة خلفيا : دراسة معملية Rani Mohamed Alzinati ; Supervised Hamdi Abualfotoh , Mostafa Helmy - Cairo : Rani Mohamed Alzinati , 2018 - 88 P. : charts , facsimiles ; 25cm

Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Prosthodontics

An in-vitro study was done to test two attachment groups medium dual retention nylon cap and medium extended range nylon cap Over which an acrylic complete overdenture the primary outcome was measuring retention force of the two attachment groups. An epoxy model was prepared with two implants in premolar area. A denture was constructed on the model with one hook in the geometric center of the denture.The forces on the denture were applied through the hook. Two attachments were constructed and picked up in the denture to be tested by applying tensile forces using a universal testing machine.In order, medium dual retention nylon cap attachment was constructed and picked up in the denture, then medium extended range nylon cap was placed in the metal housing.Every attachment subjected to five tensile forces at the Geometric center. Retention values were calculated and results were analyzed.The study concludes that: 1.using a locator as an attachment system in implant retained overdenture as a treatment plan is a simple, affordable with minimum surgical intervention. 2. Within the previous study condition the pink dual retention nylon cap show higher retention value than the red full extended nylon cap



Distally inclined implants Locator attachment Retention of implant retained overdenture