header

Effect of different locator attachment on retention of implant retained overdenture on distally inclined implants : (Record no. 73905)

MARC details
000 -LEADER
fixed length control field 02631cam a2200337 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250223032359.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 190916s2018 ua dh f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.09.09.M.Sc.2018.Ra.E
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Rani Mohamed Alzinati
245 10 - TITLE STATEMENT
Title Effect of different locator attachment on retention of implant retained overdenture on distally inclined implants :
Remainder of title An in vitro study /
Statement of responsibility, etc. Rani Mohamed Alzinati ; Supervised Hamdi Abualfotoh , Mostafa Helmy
246 15 - VARYING FORM OF TITLE
Title proper/short title تأثير الوصلات الموضعية المختلفة على استبقاء الأطقم المحمولة على غرسات مائلة خلفيا :
Remainder of title دراسة معملية
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Rani Mohamed Alzinati ,
Date of publication, distribution, etc. 2018
300 ## - PHYSICAL DESCRIPTION
Extent 88 P. :
Other physical details charts , facsimiles ;
Dimensions 25cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Prosthodontics
520 ## - SUMMARY, ETC.
Summary, etc. An in-vitro study was done to test two attachment groups medium dual retention nylon cap and medium extended range nylon cap Over which an acrylic complete overdenture the primary outcome was measuring retention force of the two attachment groups. An epoxy model was prepared with two implants in premolar area. A denture was constructed on the model with one hook in the geometric center of the denture.The forces on the denture were applied through the hook. Two attachments were constructed and picked up in the denture to be tested by applying tensile forces using a universal testing machine.In order, medium dual retention nylon cap attachment was constructed and picked up in the denture, then medium extended range nylon cap was placed in the metal housing.Every attachment subjected to five tensile forces at the Geometric center. Retention values were calculated and results were analyzed.The study concludes that: 1.using a locator as an attachment system in implant retained overdenture as a treatment plan is a simple, affordable with minimum surgical intervention. 2. Within the previous study condition the pink dual retention nylon cap show higher retention value than the red full extended nylon cap
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Distally inclined implants
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Locator attachment
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Retention of implant retained overdenture
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Hamdi Abualfotoh ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Mostafa Helmy ,
Relator term
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://172.23.153.220/th.pdf">http://172.23.153.220/th.pdf</a>
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Shimaa
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.09.09.M.Sc.2018.Ra.E 01010110079313000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.09.09.M.Sc.2018.Ra.E 01020110079313000 22.09.2023 CD - Rom 79313.CD