header

Punching shear behavior of ferrocement panels exposed to elevated temperature / (Record no. 54378)

MARC details
000 -LEADER
fixed length control field 01710cam a2200313 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field EG-GiCUC
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 160111s2015 ua dh f m 000 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-GiCUC
Language of cataloging eng
Transcribing agency EG-GiCUC
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
049 ## - LOCAL HOLDINGS (OCLC)
Holding library Deposite
097 ## - Thesis Degree
Thesis Level M.Sc
099 ## - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number Cai01.13.05.M.Sc.2015.Ah.P
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Ahmed Mohamed Saad
245 10 - TITLE STATEMENT
Title Punching shear behavior of ferrocement panels exposed to elevated temperature /
Statement of responsibility, etc. Ahmed Mohamed Saad ; Supervised Hamed Mohamed Mahmoud , Ghada Diaa
246 15 - VARYING FORM OF TITLE
Title proper/short title سلوك القص الثاقب لبلاطات الفيروسمنت المعرضة لدرجات الحرارة العالية
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Cairo :
Name of publisher, distributor, etc. Ahmed Mohamed Saad ,
Date of publication, distribution, etc. 2015
300 ## - PHYSICAL DESCRIPTION
Extent 135 P. :
Other physical details charts , facsimiles ;
Dimensions 30cm
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Sc.) - Cairo University - Faculty of Engineering - Department of Civil Engineering
520 ## - SUMMARY, ETC.
Summary, etc. The aim of this study is to investigate the behavior of ferrocement slabs exposure to elevated temperature under punching. Ten slab column connections were tested; the specimens have been divided into five groups. The test variables were the opening meshes size, diameter of meshes bars, elevated temperature exposure and fighting procedure. It is found that using ferrocement meshes instead of steel improve the punching shear resistance and the best design of ferrocement against fire consist of 10 layers with opening size 70x70 mm and 4 mm diameter
530 ## - ADDITIONAL PHYSICAL FORM AVAILABLE NOTE
Additional physical form available note Issued also as CD
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Ductility
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Ferrocement
653 #4 - INDEX TERM--UNCONTROLLED
Uncontrolled term Punching
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Ghada Diaa ,
Relator term
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Hamed Mohamed Mahmoud ,
Relator term
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Nazla
Reviser Revisor
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN)
Cataloger Soheir
Reviser Cataloger
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Thesis
Holdings
Source of classification or shelving scheme Not for loan Home library Current library Date acquired Full call number Barcode Date last seen Koha item type Copy number
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة قاعة الرسائل الجامعية - الدور الاول 11.02.2024 Cai01.13.05.M.Sc.2015.Ah.P 01010110067544000 22.09.2023 Thesis  
Dewey Decimal Classification   المكتبة المركزبة الجديدة - جامعة القاهرة مخـــزن الرســائل الجـــامعية - البدروم 11.02.2024 Cai01.13.05.M.Sc.2015.Ah.P 01020110067544000 22.09.2023 CD - Rom 67544.CD