Accuracy of stitched CBCT using small field of view in the assessment of mandibular linear measurements versus the real measurements : Pre-clinical study , Jasmine Mohammed Aly ; Supervised Hossam Kandil , Reham Hamdy , Mahmoud Abdelrauof Shalash

By: Contributor(s): Material type: TextTextLanguage: English Publication details: Cairo : Jasmine Mohammed Aly , 2018Description: 91 P. : charts , photographs ; 25cmOther title:
  • دقه القياسات الخطيه للاشعه المقطعيه مخروطيه الشعاع باستخدام مجال الرؤيه الصغيره المخيطه مقارنه بالقياسات الحقيقيه : دراسه ما قبل السريريه [Added title page title]
Subject(s): Online resources: Available additional physical forms:
  • Issued also as CD
Dissertation note: Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Oral (Radiology and Diagnosis) Summary: This preclinical study assessed the accuracy of linear measurements conducted on stitched small field of view (SSFOV) CBCT images of 15 dry human mandibles compared to the real measurements conducted directly on the mandibles using digital caliper. A composite image for each mandible was obtained by automatic and manual stitching of 7 small FOVs using the PlanmecaRomexis software. The scans were captured using PlanmecaPromax 3D MID ultra- low dose mode (ULD). The 15 mandibles were immersed under water for soft tissue simulation and all the linear measurements were conducted under the guide of RO markers. The results showed no statistically significant difference between the direct linear measurements conducted on the 15 dry human mandibles and the measurements conducted on SSFOV CBCT images. The maximum mean difference of 0.56 mm between the direct linear measurements and the SSFOV CBCT measurements. 1.01 % error was found accepted and within the limits of the 5% clinically permissible erro
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Home library Call number Copy number Status Barcode
Thesis Thesis قاعة الرسائل الجامعية - الدور الاول المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.09.05.M.Sc.2018.Ja.A (Browse shelf(Opens below)) Not for loan 01010110078976000
CD - Rom CD - Rom مخـــزن الرســائل الجـــامعية - البدروم المكتبة المركزبة الجديدة - جامعة القاهرة Cai01.09.05.M.Sc.2018.Ja.A (Browse shelf(Opens below)) 78976.CD Not for loan 01020110078976000
Browsing المكتبة المركزبة الجديدة - جامعة القاهرة shelves Close shelf browser (Hides shelf browser)
No cover image available
No cover image available
No cover image available
No cover image available
No cover image available
No cover image available
No cover image available
Cai01.09.05.M.Sc.2018.As.U Ultra-Low dose CBCT Protocol in assessment of simulated external root resorption in mandibular teeth : Preclinical study / Cai01.09.05.M.Sc.2018.Es.A Accuracy of linear measurements using ultra low dose CBCT protocol compared to standard CBCT protocol : Diagnostic accuracy study : in vitro study / Cai01.09.05.M.Sc.2018.Es.A Accuracy of linear measurements using ultra low dose CBCT protocol compared to standard CBCT protocol : Diagnostic accuracy study : in vitro study / Cai01.09.05.M.Sc.2018.Ja.A Accuracy of stitched CBCT using small field of view in the assessment of mandibular linear measurements versus the real measurements : Pre-clinical study , Cai01.09.05.M.Sc.2018.Ja.A Accuracy of stitched CBCT using small field of view in the assessment of mandibular linear measurements versus the real measurements : Pre-clinical study , Cai01.09.05.M.Sc.2018.Ma.A Assessment of the accuracy of the bisecting angle and the paralleling intraoral digital radiography using photostimulable phosphor plate (PSP), and the cone-beam computed tomography (CBCT) using ultra low dose for detection of horizontal root fractures with various angles : Invitro study / Cai01.09.05.M.Sc.2018.Ma.A Assessment of the accuracy of the bisecting angle and the paralleling intraoral digital radiography using photostimulable phosphor plate (PSP), and the cone-beam computed tomography (CBCT) using ultra low dose for detection of horizontal root fractures with various angles : Invitro study /

Thesis (M.Sc.) - Cairo University - Faculty of Oral and Dental Medicine - Department of Oral (Radiology and Diagnosis)

This preclinical study assessed the accuracy of linear measurements conducted on stitched small field of view (SSFOV) CBCT images of 15 dry human mandibles compared to the real measurements conducted directly on the mandibles using digital caliper. A composite image for each mandible was obtained by automatic and manual stitching of 7 small FOVs using the PlanmecaRomexis software. The scans were captured using PlanmecaPromax 3D MID ultra- low dose mode (ULD). The 15 mandibles were immersed under water for soft tissue simulation and all the linear measurements were conducted under the guide of RO markers. The results showed no statistically significant difference between the direct linear measurements conducted on the 15 dry human mandibles and the measurements conducted on SSFOV CBCT images. The maximum mean difference of 0.56 mm between the direct linear measurements and the SSFOV CBCT measurements. 1.01 % error was found accepted and within the limits of the 5% clinically permissible erro

Issued also as CD

There are no comments on this title.

to post a comment.

Click on an image to view it in the image viewer

Local cover image